CS-PA7DKD / CU-PA7DKD / CS-PC7DKD / CU-PC7DKD
9.3.
Outline of installation
9.3.1.
Select the best location
1. Indoor unit
There should not be any heat source of steam near the
unit.
There should not be any obstacles to prevent the air
circulation.
A place where air circulation will be good.
A place where drainage can be easily obtained.
A place where
consideration.
Do not install the unit near the doorway.
Ensure the spaces indicated by arrows from the wall,
ceiling, fence, or other obstacles.(Fig 2)
Recommended installation height for indoor unit shall be
at least 2.5m.
5cm
2. Outdoor unit
If an awning is built over the unit to prevent direct
sunlight or rain exposure, be careful that heat radiation
from the condenser is not restricted.
There should not
could be affected by hot air discharged.
Ensure the spaces indicated by arrows from the wall,
ceiling, fence, or other obstacles.(Fig 3)
noise
prevention
is taken into
5cm
Height more than
2.5m
Fig.2
be
any animals or plants which
10cm
100cm
3. Piping length and elevation
Model
PA7DKD/PC7DKD
PA9DKD/PC9DKD
5cm
38
Fig.3
Piping size
Max piping
Max piping
Liquid
length(m)
elevation(m)
Gas
3/8''
1/4''
7
7m
5m
Fig.4
10cm
5