CS-PA7DKD / CU-PA7DKD / CS-PC7DKD / CU-PC7DKD
5 cm
or more
(Left and right are identical)
Insulation of piping connections
Carry out insulation
after checking for
gas leaks and
secure with vinyl
tape.
Vinyl tape
This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
Installation parts you
should purchase ( )
Installation plate
1
Sleeve ( )
Bushing Sleeve ( )
Putty (Gum type sealer) ( )
Bend the pipe as closely on
the wall as possible, but be
careful that it doesn t break.
Vinyl tape (Wide) ( )
Apply after carrying out a
drainage test.
To carry out the drainage
test, remove the air filters
and pour water into the heat
exchanger.
Saddle ( )
Connecting cable ( )
(3-CORE WIRE/1.5 mm
PC7DKD,PC9DKD
(5-CORE WIRE/1.5 mm
+2CORE WIRE/0.50mm
PA7DKD,PA9DKD
Type designation 245 IEC 57
or heavier cord
Additional drain hose ( )
Liquid side piping ( ) 1/4"
Gas side piping ( ) 3/8"
Fig 1
36
2
)-
2
2
)-