Wiring Diagram - Panasonic cs-pa7dkd Service Manual

Air circulation up to 10.10 m3/min
Table of Contents

Advertisement

7 Wiring Diagram

CS-PA7DKD/CU-PA7DKD
CS-PA9DKD/CU-PA9DKD
Remote Control
Signal Receiver
POWER SUPPLY
POWER SUPPLY
CORD
CORD
AC 220V-230 50Hz( )
AC 220V-230 50Hz( )
INDOOR UNIT
1(L)
2(N)
3
4
TERMINAL BOARD
OUTDOOR UNIT
1(L)
2(N)
3
4
TERMINAL BOARD
Y
W
Y
COMPRESSOR
R
Y/G
R
B
OUTDOOR UNIT
CAPACITOR
INDOOR FAN MOTOR RESISTANCE( )
CS-PA7DKD
CONNECTING
CWA921308
Y-B M
395
Y-R
A
325
COMPRESSOR RESISTANCE( )
CU-PA7DKD
CONNECTING
CWB092128
3.678
C - R
C - S
7.240
AUTO SWITCH
BR
BL
Y/G
W
R
B
FUSE
102
250V 3A
Y
FAN MOTOR
B
CAPACITOR
B
CS-PA9DKD
CWA921329
390
390
CU-PA9DKD
CWB092312
3.466
3.843
ELECTRONIC CONTROLLER
FUSE
HA
1
2
3
4
Y/G
YELLOW
C
R
S
BLUE
RED
TRADE MARK
COMPRESSOR TERMINAL
OUTDOOR FAN MOTOR RESISTANCE( )
CU-PA7DKD
CONNECTING
CWA951419
Y-B
275
Y-R
260
For PA7DKD, the power source is 220V.
For PA9DKD, the power source is 220V-230V.
19
CS-PA7DKD / CU-PA7DKD / CS-PC7DKD / CU-PC7DKD
STEPPING
MOTOR
1
B
3
R
5
Y
FAN MOTOR
W
BR
BL
SENSOR(PIPING TEMP.)
SENSOR(INTAKE TEMP.)
INDOOR UNIT
R : RED
BL : BLACK
B : BLUE
BR : BROWN
O : ORANGE
GRY : GREY
G : GREEN
Y : YELLOW
W : WHITE
Y/G : YELLOW/GREEN
P : PINK
CU-PA9DKD
CWA951419
275
260

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents