Paxar Monarch Pathfinder Ultra Gold User Manual page 66

Format configurable
Table of Contents

Advertisement

Select Field Class
1. Simple Field
2. Price Field
3. System Date/Time
4. Combo
(Merged)
Enter Field Prompt
_ _ _ _ _ _ _ _ _ _ _
Enter Fixed Data
Press ENTER if none
> _ _ _ _ _ _ _ _ _ _ _ _
Enter Row #
> _ _ _
Enter Col. #
> _ _ _
Enter Density
1. 80/ 2. 120
>_
Enter Bar Height
(Units = Inch/100)
> _ _ _
Top of Field at:
1. Top of Supply
2. Left of Supply
3. Bottom of Supply
4. Right of Supply
Select Edit #1
1. (None)
2. Make into Price
3. Pad Data Field
4. Extract Chars
5. Strip Chars
6. Extract from Mid
7. Insert Chars
8. Make Shoe Size
6-8 Defining Bar Code Fields
8. Press 1 to define a simple field.
9. Type "SCAN UPC#." Press Enter.
10. Press Enter for no fixed data.
11. Type 80 for the row location. Press Enter.
12. Type 15 for the column location. Press
Enter.
13. Press 1 for the density (80%).
14. Type 40 for the bar code height (.4"). Press
Enter.
15. Type 1 for a top of supply field rotation.
16. Press Enter for no edits.