2.

Service inspection

2-1. How to activate
(1) Turn on the mixer 600 assembly while pushing the
REVERB ON switch.
About 4 seconds later, the diagnostic mode is activat-
ed, and all the LEDs on the panel are turned on (except
LED "PHANTOM CH1/2").
(2) Run application for Service inspection (Diag-
STAGEPASII-SERVICE.exe).
The following inspection screen is displayed.
Note:
If not all the LEDs on the panel are turned on, it may
be considered that a mode other than the diagnostic
mode is activated, the location of installation is mis-
taken, or there is a malfunction of peripheral circuitry.
Inspection screen (検査画面)
1. Select "STAGEPASII-SERVICE".
1
「 .
STAGEPASII-SERVICE
3. Start inspection.
3. 検査を開始します。
*
The DC-PROTECTION inspection is removed for the
default in order to operate an inner terminal.
3. Start inspection.
3.
検査を開始します。
択。
2. Tick all.
2. 全てにチェックを入れます。
2.
サービス検査
2-1. 起動方法
(1) REVERB ON スイッチを押した状態でミキサー
Ass'y の電源を入れます。
約 4 秒 後、 ダ イ ア グ モ ー ド が 起 動 し、 パ ネ ル
の LED が 全 点 灯 し ま す。 (LED "PHANTOM
CH1/2" は除きます。 )
(2) サービス検査用アプリケーション (DiagSTAGE-
PASII-SERVICE.exe)を起動します。
注:
パネルの LED が全点灯しない場合、ダイアグ
モード以外のモードで起動したか、設置ミスま
たは周辺回路の故障が考えられます。
2. Tick also detailed inspection items.
2. 詳細項目にもチェックをいれます。
※ DC-PROTECTION 検査は、内部端子を操作す
るため、デフォルト対象からはずしてあります。
STAGEPAS 600i