Superior BRT4036TEN Installation And Operation Instructions Manual page 15

Custom series decorative b-vent fireplace electronic ignition system
Table of Contents

Advertisement

10. Repeat process until both doors are evenly joined, spaced and
working freely.
CAUTION: The glass panels become very hot while
the appliance is operating. Do not attempt to adjust
or clean the glass doors until the appliance has fully
cooled.
The doors may be removed for replacement or cleaning as follows:
1. Partially open door and press up on upper spring clip with a screw
driver until outer top pivot pin is free of clip.
2. Fully fold frame assembly and slide upper edge towards center of
firebox opening until guide pins are free of frame rail (see Figure 35).
CAUTION: Always operate the appliance with the
doors either fully opened or fully closed. Operating
the appliance with the doors partially open can result
in improper venting of flue products.
WARNING: Discontinue use of the appliance imme-
diately if doors are damaged and contact a qualified
installer for repair. Only doors certified with the ap-
pliance shall be used.
WARNING: Do not slam or strike doors. Damage
can result in a hazardous condition.
Spring
Clip
Side
Front
Face
Partially
Opened
Door
Figure 34 - Adjusting Glass Doors
126737-01_E
INSTALLATION Continued
OPENING VENT DAMPER
Vent damper must be locked in the full open position before operating
Hold-Down
fireplace. If vent damper is not open, fireplace will not light.
Screw
SuperiorFireplaces.US.com
Fold Bi-Fold
Spring Clip
Door After
Releasing
Spring Clip
and Slide
Door Out of
Upper Track
Remove Bottom Pin
From Pivot Plate While
Sliding Door Out of the
Upper Track
Figure 35 - Removing Glass Doors
VENT DAMPER MUST BE LOCKED
IN THE FULL OPEN POSITION
TO OPERATE THE APPLIANCE
OPEN
Figure 36 - Opening Vent Damper
Press
Spring Clip
to Release
Pivot Pin
Pivot Plate
CLOSE
15