Superior BR-42 Installation Instructions Manual

Standard series 42" wood burning fireplaces

Advertisement

RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
INSTALLATION
INSTRUCTIONS
42" Wood Burning Fireplaces
P/N 700,026M REV. C 11/2003
MODELS
BR-42
BRI-42
BR-42-2
This installation manual will enable you to obtain a safe, efficient and
dependable installation of your fireplace system. Please read and under-
stand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any
circumstances. Any modification or alteration of the fireplace system,
including but not limited to the fireplace, chimney components and
accessories, may void the warranty, listings and approvals of this system
and could result in an unsafe and potentially dangerous installation.
IMPORTANT! TO ASSURE PROPER ALIGNMENT OF GLASS DOORS:
INSTALL THIS FIREPLACE IN A SQUARE AND PLUMB CONDITION,
USING SHIMS AS NECESSARY AT SIDES AND/OR BOTTOM.
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
STANDARD SERIES
WH Report No. J99025865B-231
BC-42
BCI-42
BC-42-2
1

Advertisement

Table of Contents
loading

Summary of Contents for Superior BR-42

  • Page 1 INSTRUCTIONS STANDARD SERIES 42" Wood Burning Fireplaces P/N 700,026M REV. C 11/2003 MODELS BR-42 BRI-42 BR-42-2 This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and under- stand these instructions before beginning your installation.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Safety Rules ... page 2 Tools and Building Supplies ... page 2 Precautions ... page 3 Introduction ... page 3 Clearances/Height Requirements ... page 3 Chimney System ... page 3 Assembly Outline ... page 4 Location of Fireplace ... page 4 Assembly Steps ...
  • Page 3: Precautions

    PRECAUTIONS Note: These fireplace systems are not difficult to install. However, in the interest of safety, it is recommended that the installer be a quali- fied or certified “tradesman” familiar with com- monly accepted fireplace installation and safety techniques as well as prevailing local codes. The most important areas of concern dealing with the installation of factory-built fireplaces are clearances to combustible materials, proper...
  • Page 4: Assembly Outline

    Insulate Joists Same As Ceiling Draft Stops Firestop CTDT Termination Note: Non- Combustible Chase Flashing Must Be Used To Cover Chase Opening Level Solid Continuous Surface Insulation (Thermal Barrier) Figure 2 WARNING: IF INSULATION IS USED, THE FIREPLACE MUST NOT BE PLACED DI- RECTLY AGAINST IT.
  • Page 5: Assembly Steps

    ASSEMBLY STEPS Note: The following steps represent the normal sequence of installation. Each installation is unique, however, and might require a different sequence. 1. Position firebox prior to framing or into prepared framing. 2. Install the chimney system. 3. Connect house wiring to the fireplace for later attachment of optional blower.
  • Page 6: Fireplace Specifications

    " Metal Safety Strips Figure 8 Metal Safety Strips Figure 9 Step 3. Refer to fireplace drawings and specifi- cations on pages 6 and 7 for framing dimensions and details. Frame appliance enclosure as illus- trated in Figures 11 through 14 on page 8. IMPORTANT: UNDER NO CIRCUMSTANCES CAN THE FIREPLACE TOP SPACERS ( FIGURE 10 ) BE REMOVED OR MODIFIED, NOR MAY...
  • Page 7: Framing Specifications

    FRAMING SPECIFICATIONS (See Note) Header Fireplace Framing Note: When Framing With 6” Studs Header Must Be 17” (432mm) Higher. Use Security Chimney’s OR15 Offset/Return Elbow To Recess The Chimney Back 2 1/2” (64mm). Flat Frame Down To A False Header At (B). Maintain Required Clearance To Chimney At All Times.
  • Page 8: Installing The Chimney System

    Step 4. Fireplace should be secured to side framing members using the full length nailing tabs at the top and bottom of the fireplace front face. Use 8d nails ( Figure 17 ). 8d Nail Figure 17 Note: The nailing tabs and the area directly behind the nailing tabs are exempt from the clearances described on page 5.
  • Page 9: Offset Through Floor/Ceiling

    Note: If there is a room above ceiling level, firestop spacer must be installed on the bottom side of the ceiling. If an attic is above ceiling level, firestop spacer must be installed on top side of ceiling joist (Figures 21 and 22 ). Room Above Firestop Spacer Figure 21...
  • Page 10 Security's chimney sections do not need to be screwed together. Additional reinforcement is not necessary except in certain offset condi- tions (refer to page 14, Figure 39 ). Step 5. The height of vertical chimney pipe supported only by the fireplace must not ex- ceed 30'.
  • Page 11: Ten Foot Rule Summary

    Termination Chimney Figure 34 4. Pull up slightly on CTD to ensure locking joint has firmly engaged. Using a FTF8-CTDT Chase Termination: Refer to specific installation instructions in- cluded with the FTF8-CTDT chase termination for clearance and installation details. Using a FTF8-CT1 Chase Termination: Refer to specific installation instructions in- cluded with FTF8-CT1 chase terminations for clearance and installation details.
  • Page 12: Special Offset Instructions

    4. Determine amount of chimney height re- quired by subtracting total combined height of all pre-selected components (fireplace and chimney components from total desired height.) Reference Vertical Elevation Chart and deter- mine the number of chimney sections (quantity and length) required. SPECIAL OFFSET INSTRUCTIONS To clear any overhead obstructions, you may offset your chimney system using Security's...
  • Page 13: Offset Elevation Chart

    Return Elbow Max. Stabilizer 10' Max. Offset Elbow Figure 37 Figure 38 OFFSET ELEVATION CHART FTF8-ES30 Offset Height Offset/Return FTF8-S4 (Inches) (Inches) Elbow Stabilizer NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Number of FTF8 Chimney Sections 12" 18" 38" 48"...
  • Page 14: Installing Offsets

    Joints Chimney Section No. 8 x 1/2" SMS Figure 39 Underside Of Chimney Figure 40 FTF8-E30 Return Elbow* Chimney Section (S) FTF8-30 Offset Elbow* *Part of Offset/Return Package Model FTF8-ES30 Figure 41 INSTALLING OFFSETS First, review the Offset Elevation Chart and Figure 41 for reference.
  • Page 15: Combustion Air Kits

    THIS FIREPLACE IS NOT INTENDED TO BE USED AS A SUBSTITUTE FOR A FURNACE TO HEAT AN ENTIRE HOME. USE FOR SUPPLE- MENTARY HEATING ONLY. BLOWER THREE PRONGED PLUG TO GROUNDED OUTLET Figure 44 The FBK-100/200 Blower Kits are design certi- fied by Warnock Hersey for use with these appliances.
  • Page 16: Glass Doors

    THE KNOCKOUT IS ALWAYS REMOVED FROM INSIDE THE FIREPLACE. DO NOT REMOVE THE KNOCKOUT UNLESS YOU ARE INSTALL- ING A GAS LINE. If removal is attempted from the outer wrapper, side refractory damage may occur. With a medium-sized hammer, lightly tap the surface of the indentation.
  • Page 17 If fireplace is installed diagonally across a 90 corner; no wall shields are required. Hearth Extension Dimensions 16" 35" 8" 51" Figure 48 Wall Shield Required Where Less Than 12" 36" 36" Figure 49 Methods of Determining Hearth Extension and Wall Shield Equivalents To determine the thickness required for any material when either the k or r values are known:...
  • Page 18: Finish Requirements

    " marble slab set in " mortar covers the brick, “R” for the marble and mortar becomes: “R” = r x T = 0.09 x " = .068 “R” = r x T = 0.20 x " = .10 The sum of all “R values” is: .70 + .10 +.
  • Page 19: Installation Components

    INSTALLATION COMPONENTS Outside Combustion Air Kits (with duct) 81L87 FOAK (without duct) 81L88 FOAK-LD Combination Offset/Return Elbow 63L28 FTF8-OR15 Firestop Spacer (Flat) 63L29 F8FS Firestop Spacer (Flat) 63L31 F8FS-2 Firestop Spacer (30 ) 63L30 F8FS30 Firestop Spacer (30 ) 63L32 F8FS30-2 Cold Climate Kit 63L65...
  • Page 20 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2001 by LENNOX P/N 700,026M REV.

This manual is also suitable for:

Bri-42Br-42-2Bc-42Bci-42Bc-42-2

Table of Contents