Superior Custom Series Installation And Operation Instructions Manual

Superior Custom Series Installation And Operation Instructions Manual

Decorative b-vent fireplaces millivolt system

Advertisement

Quick Links

P/N 900806-00 REV. G 9/2019
Ce manuel est disponible en francais, simplement en
faire la demande. Numéro de la pièce 900806-02.
P900806-00
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
Decorative Product: Not for use as a heating
appliance.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
C
US
Report No. F09-143
NOTE: DIAGRAMS AND ILLUSTRATIONS THROUGHOUT THE MANUAL ARE NOT TO SCALE.
Installation and Operation Instructions
Custom Series Decorative B-Vent Fireplaces
Millivolt System
Models
BRT4336TMN-B
BRT4336TMP-B
BRT4536TMN-B
BRT4536TMP-B
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
NOTICE: Fireplace is not to be operated by a
thermostat.
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
BRT4342TMN-B
BRT4342TMP-B
BRT4542TMN-B
BRT4542TMP-B

Advertisement

Table of Contents
loading

Summary of Contents for Superior Custom Series

  • Page 1 Installation and Operation Instructions Custom Series Decorative B-Vent Fireplaces Millivolt System P/N 900806-00 REV. G 9/2019 Models Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 900806-02. BRT4336TMN-B BRT4336TMP-B BRT4342TMN-B BRT4342TMP-B BRT4536TMN-B BRT4536TMP-B BRT4542TMN-B BRT4542TMP-B Report No.
  • Page 2: Table Of Contents

    Thank you for your purchase. We appreciate your TABLE OF CONTENTS business! Safety ..................... 3 Please carefully read and follow all instructions in this manual. Pay Unpacking ..................4 special attention to all warnings and safety information. Introduction ................... 5 Following these safety, care, and operation instructions will help Selecting Location ................
  • Page 3: Safety

    SAFETY Continued 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other WARNING gases unless a certified kit is used. This product can expose you to chemicals includ- 2.
  • Page 4: Unpacking

    SAFETY Continued COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS 17. Do not use fireplace if any part has been exposed to or under These appliances are approved for installation in the US state of Mas- water. Immediately call a qualified service person to arrange for sachusetts if the following additional requirements are met: replacement of the unit.
  • Page 5: Introduction

    INTRODUCTION Continued 2. Consider a location where heat output would not be affected by WARNING: Installation of this appliance should be drafts, air conditioning ducts, windows or doors. done by a qualified service person well trained in the 3. A location that avoids the cutting of joists or roof rafters will make installation of such appliances.
  • Page 6: Product Specifications

    PRODUCT SPECIFICATIONS GAS RATING - NATURAL BRT4336TMN-B, BRT4536TMN-B BRT4342TMN-B, BRT4542TMN-B Max. Input Rating: 40,000 Btu/Hr 45,000 Btu/Hr Manifold Pressure: 3.5" WC (.87 kPa) 3.5" WC (.87 kPa) Minimum Supply Pressure: 4.5" WC (1.12 kPa) 4.5" WC (1.12 kPa) Maximum Supply Pressure: 10.5"...
  • Page 7: Pre-Installation Preparation

    PRE-INSTALLATION PREPARATION MANTEL CLEARANCES AND WALL DETAILS CLEARANCES Minimum clearances to combustibles are: A combustible mantel shelf maybe installed a maximum 12" (22.9 cm) from the wall. Figures 5 and 6 show the minimum allowable distances Back and Sides of Outer Surround 0"...
  • Page 8 PRE-INSTALLATION PREPARATION Continued FRAMING These Dimensions Allow for a 3/4" Clearance at Sides and 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Back of Fireplace. However, 0" Clearance is Permitted. NOTE: If a wall covering is used to line the enclosure, then all mea- surements must be from the surface of the covering.
  • Page 9: Venting Installation

    VENTING INSTALLATION A B-type venting system must be connected to the appliance for IMPORTANT NOTICE venting to the outside of the building. The following section is provided as a guide to a standard B-type ANSI Z223.1/NFPA 54 (USA), or CSA B149.1 (Canada) vent installation.
  • Page 10 VENTING INSTALLATION Continued Some codes areas allow the use of existing B-type vent systems if CHECKING FOR PROPER VENTING the system is at or above the recommended diameter of the flue, in After completing and checking electrical, gas and vent connections, this case 6".
  • Page 11: Installation

    INSTALLATION WALL SWITCH INSTALLATION The installation of a wall switch allows you to activate the gas control valve without normal household electricity since valve operates on millivolt current supplied by heat generated by the thermopile. To install wall switch: 1. Remove front refractory access panel by lifting up and angling out of firebox opening (see Figure 13).
  • Page 12 INSTALLATION Continued GAS LINE HOOK-UP WARNING: Gas line hookup should be done by your Incoming 1/2" Gas gas supplier or a qualified service person. Line Permitted by Local Codes WARNING: Before you proceed, make sure your Sediment gas supply is OFF. Trap (Not 3"...
  • Page 13 INSTALLATION Continued Complete your gas installation by connecting incoming gas line with flexible gas line. Secure tightly with wrench but DO NOT OVERTIGHTEN. EMBER AND PAN MATERIAL PLACEMENT 1. Open bag(s) of vermiculite and fill until it is even across burner pan (see Figure 19). 2.
  • Page 14 INSTALLATION Continued INSTALLATION Continued LOG PLACEMENT FOR BRT4336-B AND BRT4536-B MODELS Log 4 Log 3 1. Place small front right log (log 1) on right front of grate as shown in Figure 22. 2. Place large back log (log 2) onto grate making sure notches rest over grate as shown in Figure 22.
  • Page 15 INSTALLATION Continued LOG PLACEMENT FOR BRT4342 AND BRT4542 MODELS 1. Place large back log (log 1) onto grate making sure notches rest Log 3 over grate (see Figure 26). Log 4 2. Insert lower end of log 2A between first two grate fingers and position upper end into notch on front of log 1.
  • Page 16 INSTALLATION Continued COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) INSTALLING OPTIONAL GLASS DOOR ACCESSORY The outside air kit may be installed on the left side of fireplace only. The vent can be installed through any outside wall a minimum of three CAUTION: Use only glass doors certified for use feet below fireplace termination cap.
  • Page 17 INSTALLATION Continued 6. Repeat the process for the opposite door assembly. Spring Clip Fold Bi-Fold Door 7. To adjust doors, slide them partially open. Using a screwdriver, After Releasing loosen hold-down screws in the spring clip (see Figure 33) and Spring Clip and pivot plate.
  • Page 18: Operation

    OPERATION 10. Push in knob all the way and hold in. Immediately light the pilot FOR YOUR SAFETY manually. Continue to hold control knob in for about one minute READ BEFORE LIGHTING after pilot is lit. Release knob and it will pop back up. Pilot should remain lit.
  • Page 19: Inspecting Pilot And Burner Flame Patterns

    INSPECTING PILOT AND BURNER FLAME PATTERNS CLEANING AND MAINTENANCE Periodically check pilot flame pattern and burner flame patterns often. WARNING: Installation and repair should be done PILOT ASSEMBLY by a qualified service person. The appliance should The pilot assembly is factory preset for the proper flame height. be inspected before each use and at least annually Alterations may have occurred during shipping and handling.
  • Page 20: Wiring Diagram

    WIRING DIAGRAM PILOT BURNER THERMOPILE DO NOT IGNITOR CONNECT TO 120V REPLACE FACTORY WIRING WITH 105°C EQUIVALENT OR HIGHER RATING PILOT GAS LINE EXTERNAL WIRING USE ONLY CLASS 2 THERMOSTAT WIRE 18 GA. RED/WHITE N.C.SW WHITE (VENT SAFETY SHUTOFF SWITCH) N.O.
  • Page 21: Troubleshooting

    TROUBLESHOOTING NOTE: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging pilot and/or gas control valve filter OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Pilot will not light...
  • Page 22 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. •...
  • Page 23: Service Hints

    SERVICE HINTS REPLACEMENT PARTS See Pages 24 to 27 for a complete replacement parts list. Use only When Gas Pressure Is Too Low parts supplied from the manufacturer. • pilot will not stay lit Normally, all parts should be ordered through your IHP distributor •...
  • Page 24: Parts

    PARTS WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. MODEL CAT. NO. INTERIOR F3198 BRT4536TMN-B White Herringbone F3199 BRT4536TMP-B White Herringbone...
  • Page 25 PARTS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on Page 23 of this manual. KEY NO. CATALOG NO. DESCRIPTION 36" Models 42" Models J6811 MICRO SWITCH • • J4667 SCREW, #10 X 5/8 PH AB BLK •...
  • Page 26 PARTS WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. BRT4336 BRT4536 NO. CATALOG NO. DESCRIPTION White Stacked White Herringbone F3225 Refractory Set, White Herringbone...
  • Page 27 PARTS WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. LOG SETS FOR 36"MODELS LOG SETS FOR 42" MODELS BRT4336 BRT4536 BRT4342...
  • Page 28: Accessories

    ACCESSORIES NOTICE: All accessories may not be available for all fireplace models. CAT NO. MODEL DESCRIPTION EXTRUDED ALUMINUM BI-FOLD GLASS DOORS F0981 BD36 36" Standard Bi-Fold Glass Door - Black finish F0984 BD42 42" Standard Bi-Fold Glass Door - Black finish OPTIONAL OUTSIDE AIR KITS Optional kit helps offset the negative pressure often existing in today's tightly constructed homes.
  • Page 29 ACCESSORIES Continued CAT NO. MODEL DESCRIPTION PERIMETER TRIM KIT F1042 PT36 36" Perimeter Trim Kit - Black F1045 PT42 42" Perimeter Trim Kit - Black PROPANE/NATURAL GAS CONVERSION KIT F1122 PCBM-36 36": Millivolt - NG to LP F1123 NCBM-36 36": Millivolt - LP to NG (Not Shown) F1126 PCBM-42...
  • Page 30 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ SuperiorFireplaces.us.com 900806-00G...
  • Page 31: Warranty

    ® 20 Year Limited Warranty THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials ® and workmanship at the time of manufacture. The product body, firebox and barrier carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 32 SuperiorFireplaces.us.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name IHP reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Table of Contents