STATIFLEX 200-M

statiFlex 200-m dual arm

NOTE: The Statiflex 200-M Dual Arm should be mounted between
Installation Steps:
two SF2400 extraction fans.
8.5 ft
(2600 mm)
Recommended
9.06 in.
(230 mm)
1. Loosen latches and remove the filter cover. See Figure A.10.
FIGURE A.10
LATCH
FIGURE A.9
5 ft (1525 mm)
Minimum
38-43.5 in.
(965-1105 mm)
FILTER COVER
ATTENTION
The SF 2400 which is mounted right of the
Statiflex 200-M filter unit will be in reverse
position, resulting in centerpoints of fan
outlet and filter inlet not aligning. This will
not affect system performance.
9
ft
(2745 mm)
Recommended
10. in.
(250 mm)
2. Using a multi-purpose power saw cut open through the scribe
marks both inlets of bottom housing; cutouts to be Ø 8 in. (200
mm). See Figure A.11.If using a 6 in. diameter hose, cut open
through the scribe mark on the 6 in. side of the inlets of bottom
housing.
FIGURE A.11
BOTTOM
HOUSING
INLET
A-6
INSTALLATION