STATIFLEX 200-M
WARNING
Only use the product for the welding
processes described in the General
Description. Avoid using the product for
extracting and/or filtering fumes and gases which are
released during the following (welding) processes:
oxy-fuel cutting
aluminum laser cutting
oil-treated metal
arc-air gouging
oil mist
paint mist
heavy oil mist in welding fume
hot gases (more than 40°C/100°F continuously)
aggressive gases (e.g. from acids)
plasma cutting
grinding aluminum and magnesium
flame spraying
extraction of cement, saw dust, wood dust etc.
sucking cigarettes, cigars, oiled tissues and other
burning particles, objects and acids
in all situations where explosions can occur
(This list is not comprehensive.)
If the product is used in above situations it could result in
potential fire hazard, non-compliance with local
regulations and reduction in product performance and
life.

users

This product should only be used by authorized, trained and
qualified users.

intended use

The product has been designed exclusively for filtering fume
which is released during common weld processes. Using the
product for other purposes is considered contrary to its intended
use. Lincoln Electric accepts no liability for any damage resulting
from such use. Only use the product in mechanically sound
condition in accordance with its intended use and the instructions
set forth in the user manual.

modiFiCations

Modifications of this product, other than those specified in this
manual, are not allowed. Modifications will void the product
warranty.

oPeration

The operation description below applies to all versions of the base
unit. The air which contains welding fume is captured, extracted
and filtered, in which the filtered air can be either recirculated or
exhausted.
First, the welding fume is extracted through one or two
adjustable fume extraction arm(s) by one or two external
extraction fan(s).
Second, the fan unit(s) exhaust(s) the welding fume via a hose or
duct into the Statiflex 200-M filter unit.
Third, as the welding fume enters the Statiflex 200-M unit, it
passes through the prefilter in the center of the LongLife filter
cartridge. The prefilter separates larger particles, debris and
sparks prior to the welding fume entering the LongLife filter.
Fourth, the welding fume passes through the LongLife filter
cartridge (stabilized).
Fifth, after passing through the LongLife filter, the filtered air
exits the Statiflex 200-M via the outlet opening(s) at top of unit. If
desired, and local or federal regulations permit, filtered air can
be recirculated back into work environment or exhausted outside
of building.