Outdoor Fan Control - Fujitsu AB*G14LVTA Service Instructions Manual

Universal floor / ceiling slim duct / compact cassette compact wall mounted / wall mounted / floor inverter multi
Hide thumbs Also See for AB*G14LVTA:
Table of Contents

Advertisement

5. OUTDOOR FAN CONTROL

1. Outdoor Fan Motor
Following table 3 shows the fan speed of the outdoor unit.
( Table 3 : Fan speed of the outdoor unit )
AO*G18LAT3
AO*G24LAT3
AO*G30LAT4
It runs at 500rpm for 20 seconds after starting up the outdoor fan.
*
AO*G18/ 24LAT3
When the outdoor heat exchanger temperature is lower than 1°C,
the fan speed switches to 780rpm on heating mode.
AO*G30LAT4
When the outdoor heat exchanger temperature is lower than 2°C,
the fan speed switches to 850rpm on heating mode.
Cooling
780/ 730/ 400/ 300/ 250/ 200 rpm
850/ 820/ 780/ 400/ 300/ 200 rpm
Heating
780/ 730/ 660/ 400/ 300/ 250/ 200 rpm
850/ 780/ 400/ 300/ 200 rpm
01-17

Advertisement

Table of Contents
loading