< AB*G / AU*G type >
When Indoor heat exchanger
temperature rises
Hi
42°C
*
Me+ or setting
39°C
FAN mode
*
Lo or setting
37°C
FAN mode
Cool air
prevention
30°C
S-Lo
*
Lower speed is selected
During 10°C HEAT OPERATION
< AS*G / AU*G / AB*G type >
When Indoor heat exchanger
temperature rises
Auto
39°C
Lo
< AG*G type >
When Indoor heat exchanger
temperature rises
Auto
39°C
Lo
When Indoor heat exchanger
temperature rises
When Indoor heat exchanger
temperature drops
37°C
34°C
32°C
24°C
When Indoor heat exchanger
temperature drops
34°C
When Indoor heat exchanger
temperature drops
31°C
01-10
< AG*G type >
Hi
42°C
*
Me or setting
39°C
FAN mode
*
Lo or setting
37°C
FAN mode
Cool air
prevention
30°C
S-Lo
*
Lower speed is selected
< AR*G type >
When Indoor
heat exchanger
temperature rises
Auto
37°C
Lo
When Indoor heat exchanger
temperature drops
34°C
31°C
29°C
24°C
When Indoor heat exchanger
temperature drops
32°C