Figure 8-6: Udp Redirect Frame Example; Table 8-10: Osi Model For Compact Outdoor Sspa Ethernet Ip Interface - Paradise Datacom RA 5785 Operation Manual

Mini compact outdoor solid state power amplifier
Table of Contents

Advertisement

low overhead resulting in minimal impact to network performance. The control application
sends a UDP request to SSPA unit and waits for response. The length of time the control
application waits depends on how it is configured. If the timeout is reached and the control
application has not heard back from the agent, it assumes the packet was lost and
retransmits the request. The number of the retransmissions is user configurable.
The Paradise Datacom SSPA Ethernet IP interface can use UDP ports from 0 to 65553 for
sending and receiving. The receiving port needs to be specified through the front panel menu.
For sending, it will use the port from which the UDP request originated. Of course, it is up to
the user to select an appropriate pair of ports that are not conflicting with standard IP ser-
vices. Paradise Datacom recommends usage of ports 1038 and 1039. These ports are not
assigned to any known application.
As an application layer protocol (which actually carries meaningful data), the standard SSPA
serial protocol was selected. This protocol proves to be extremely flexible and efficient. It is
also media independent and can be easily wrapped into another protocol data frame. An ex-
ample of the UDP frame with encapsulated Paradise Datacom protocol frame is shown on
Figure 8-6.
UDP Header
(8 bytes)
A detailed OSI model for the RM SSPA M&C interface is represented in Table 8-10.

Table 8-10: OSI Model for Compact Outdoor SSPA Ethernet IP Interface

OSI Layer
Protocol
Paradise Datacom CO
Application
SSPA Serial Protocol
Transport
UDP
Network
IP
Data Link
Ethernet
Standard CAT5 (CAT
Physical
6) Network Cable
This set of Ethernet IP protocols is currently supported by Paradise Datacom Universal M&C
package (Compact Outdoor SSPA). The software is supplied on CD with the unit, or can be
downloaded by registered users from the company web site, http://www.paradisedata.com.
Operations Manual, HPA3, Mini Compact Outdoor SSPA
SSPA Serial Protocol Frame
(11+N Bytes, 0<N<128)

Figure 8-6: UDP Redirect Frame Example

Notes
Frame structure described in Section 8.0
Connectionless transport service. MTU on target PC
must be set to accommodate largest SSPA Serial Pro-
tocol Frame. Set MTU to a value larger than 127 bytes.
ARP, RARP and ICMP Ping protocols supported by
RM SSPA controllers. Static IP Address only, no DHCP
support.
10/100 Base-T Network
Maximum node length 100 m
208143 REV -
CRC 16
checksum
71

Advertisement

Table of Contents
loading