3.0 Introduction

The Mini Compact Outdoor SSPA is available with a standard Ethernet & RS232/485
interface. This section summarizes the connections to a remote computer for various remote
communications. Table 3-2 summarizes the hardware connections of Port J4 for all remote
communication connections.

3.0.1 Remote Communications Connections

Units can be configured for either Ethernet (default IP or user-defined IP), RS-485, or RS-232
communications. The units cannot be used simultaneously with multiple communication
protocols. The user must select one of the four formats. Figures 3-1 through 3-4 show the
proper configuration of J4 for each of the four communication formats.
Interface Select 0
Chassis Ground
TX Enable
10 BASE-T RX-
10 BASE-T RX+
10 BASE-T TX+
10 BASE-T TX-
DEFAULT IP ADDRESS: 192.168.0.9

Figure 3-1: J4 Connections for Ethernet Communications, Default IP Address

Interface Select 1
Chassis Ground
TX Enable
10 BASE-T RX-
10 BASE-T RX+
10 BASE-T TX+
10 BASE-T TX-
USER-DEFINED IP ADDRESS

Figure 3-2: J4 Connections for Ethernet Communications, User-Defined IP Address

Operations Manual, HPA3, Mini Compact Outdoor SSPA
Section 3: Quick Start and Operation