Table 8-7: System Settings Data Values - Paradise Datacom RA 5785 Operation Manual

Mini compact outdoor solid state power amplifier
Table of Contents

Advertisement

Data
# Bytes
Address
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
1
10
1
11
1
12
1
13
1
14
1
15
1
16
1
17
1
18
1
19
1
20
1
21
1
22
1
Note: Data length must be at least two bytes to form integer with the lower byte sent first. If an odd number of bytes is received, the last byte
will be saved as the lower byte of the integer and the upper part will be zero.
Operations Manual, HPA3, Mini Compact Outdoor SSPA

Table 8-7: System Settings Data Values

Description
System Operation Mode
System Hierarchical Address
Unit Start Up State
(in Redundancy)
Mute State
Attenuation Level
(dB down from maximum gain)
RESERVE
Amplifier Network Address
High Temperature Alarm Threshold
SSPA module Calibration Mode
SSPA Spare Fault Status
SSPA Spare Fault Handling
Auxiliary Fault Status
Auxiliary Fault Handling
BUC Fault Status
BUC Fault Handling
Protocol Select
Baud Rate Select
Fiber Optic Fault Status
Fiber Optic Fault Handling
Standby Mode
BUC Reference
Forward RF Fault Status
(continued)
208143 REV -
Limits and Byte Values
Single Amplifier = 255
1:1 Redundant = 0
Unit 1= 0; Unit 2= 255
On Line Amplifier = 255
Standby Amplifier = 0
Mute Clear (Transmit Enable) = 255
Mute Set (Transmit Disable) = 0
[1 bit for every 0.1 dB]
0 dB attenuation = 0
20 dB attenuation = 200
N/A
1 to 255
0 to 100 (in
Temperature Compensated = 255 (normal state)
Tune Mode = 1 (Factory Use Only)
Calibration Mode = 0 (Factory Use Only)
Ignore Spare Fault = 255
Fault on value of window on ADC channel = 0 to 1
Fault on External Mute = 8
Minor Fault (no effect on Summary Fault) = 255
Major Fault (Triggers Summary Fault) = 0
Major Fault with Mute (Transmit Disabled) = 1
Disabled = 255
Fault High = 0
Fault Low = 1
Minor Fault (no effect on Summary Fault) = 255
Major Fault (Triggers Summary Fault) = 0
Major Fault with Mute (Transmit Disabled) = 1
Enabled = 0
Disabled = 255
Minor Fault (no effect on Summary Fault) = 255
Major Fault (Triggers Summary Fault) =0
Major Fault with Mute (Transmit Disabled) = 1
Serial = 255
IPNET (Ethernet UDP, Web M&C) = 3
SNMP = 4
9600 = 255
38400 = 0
19200 = 1
4800 = 2
2400 = 3
Disabled = 255
Fault on Logic High = 0
Fault on Logic Low = 1
Minor Fault (no effect on Summary Fault) = 255
Major Fault (Triggers Summary Fault) =0
Major Fault with Mute (Transmit Disabled) = 1
Hot standby=255; Cold standby=0
Autoswitch = 0; External = 1; Internal = 2
Disabled = 255
Low RF Fault Threshold = 0
RF Window @ 10% = 1
RF Window @ 15% = 2
High RF Threshold = 3
o
C)