Parts That Operate When The Power Switch (Sw2) Is Turned On - Konica Minolta BIZHUB 750 Service Manual

Hide thumbs Also See for BIZHUB 750:
Table of Contents

Advertisement

Theory of Operation Ver1.0 Aug.2005
26.3.3

Parts that operate when the power switch (SW2) is turned ON

A. Composition
CBR1
CBR2
B. Operation
When the power switch (SW2) is turned ON with the main power switch (SW1) ON, the DC power source /1
(DCPS1) supplies the 24V DC power source system for the drive of various types of load in addition to the
power source systems that have been supplied so far. And also, it also supplies the AC power source to the fus-
ing heater lamp /1 (L2), /2 (L3), and /3 (L4) when the main relay (RL1) turns on. In this manner, each of the
boards are supplied with the power source to start the initial operation of the main body.
SW1
NF
Coil/2
RL1
DCPS1
5VDC
12VDC
24VDC
RL1
IPB
PRCB
26. OTHERS
L2
L3
L4
SW2
SCB
57aat2e015na
107