Step 1.4 Taping The Pipes, Cables, And Drain Hose - Samsung AR09KSFPDWQN User Manual

Table of Contents

Advertisement

Left
<Possible directions of the pipe bundle>
CAUTION
If changing the pipe direction from left to right, do not
drastically bent it but slowly turn it in the opposite
direction as shown. Otherwise, the pipe may be
damaged in the process.
<Minimum distances between the hole
and the installation plate>
Model
A
1.2(30)
09/12
1.5(38)
18/24
Pipe bundle hole: Ø 2.56 inch (Ø65 mm)
36 English
Right
Rear right or left
t
Bottom righ
Pipe bundle hole
(Unit : inch (mm))
B
C
D
3.8(96)
1.5(38)
1.2(30)
5.0(126)
2.8(70)
1.5(38)
Pipe bundle hole
1. Drill the hole.
CAUTION
Be sure to drill only one hole.
Make sure that the hole slants downwards so that the
drain hose slants downwards to drain water well.
Indoor unit
<The hole slants downwards>
Step 1.4 Taping the pipes, cables, and
drain hose
1. Wrap foam insulation on parts without
insulation on the ends of the refrigerant
pipes, as shown in the figure. This
wrapping minimises condensation problem.
Insulation
Refrigerant pipes
2. Wind the refrigerant pipes, power cable,
communication cable and drain hose with
vinyl tape to make a pipe bundle.
Installation plate
Vinyl tape
Power and communication cables
(assembly cable)
Drain hose
Wall
Drain hose
Refrigerant pipes
(assembly pipe)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar**ksfp** series

Table of Contents