Preparation; Step 1.1 Choosing The Installation Location - Samsung AR09KSFPDWQN User Manual

Table of Contents

Advertisement

Preparation

Step 1.1 Choosing the installation
location
Overview of installation location requirements
4.9inch
(125 mm)
or more
Drain hose hole
You can select the direction of
draining (left or right).
Maximum pipe height: 49.2ft(15m)
Maximum pipe length: 98.4ft(30 m)
Make at least one round to
reduce noise and vibration.
The actual units may look different from
the images depicted here.
Pipe length
Model
Minimum
09/12
9.8ft(3m)
18/24
9.8ft(3m)
Outdoor
Unit
CAUTION
Outer wall
Indoor
Unit
Cut insulation to have
rainwater drained
3.9inch(100 mm) or more
4.9inch
(125 mm)
or more
Pipe height
Maximum
Maximum
49.2ft(15m)
26.2ft(8m)
98.4ft(30m)
49.2ft(15m)
Make a U-trap (A) on the pipe
(which is connected to the
indoor unit) at outer wall and
cut the bottom part of the
insulation (about 0.4inch(10
mm)) to prevent rainwater
from getting inside through
the insulation.
CAUTION
Comply with the length and height limits described in
the figure above.
Minimum clearances for the outdoor unit
Wall
Minimum clearance in inch
23.6
Air flow direction
Top view
When installing 1 outdoor unit
(6 cases)
5.9
23.6
11.8
Side view
(Unit: inch)
78.74
English
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar**ksfp** series

Table of Contents