Outdoor Unit Installation; Step 3.1 Fixing The Outdoor Unit In Place; Refrigerant Pipes - Samsung AR09KSFPDWQN User Manual

Table of Contents

Advertisement

Outdoor Unit Installation

Step 3.1 Fixing the outdoor unit in
place
Rubber leg
(Unit : ft/mm)
Model
09/12
18/24
1. Place the outdoor unit as directed on the
top of the unit to let the discharged air out
properly.
2. Fix the outdoor unit in level to an
appropriate support using anchor bolts.
NOTE
Secure the rubber legs to help prevent the generation
of noise and vibration.
If the outdoor unit is exposed to strong winds, install
shield plates around the outdoor unit so that the fan
can operate correctly.
44 English
X
X
Y
2.01ft
1.04ft
(612mm)
(317mm)
2.16ft
1.12ft
(660mm)
(340mm)
Optional: Fixing the outdoor unit to a wall with
a rack
Soft rubber designed to cut off vibration from rack
to wall (not supplied with product)
Soft rubber designed to cut off residual vibration from
outdoor unit to rack (not supplied with product)
NOTE
Make sure that the wall can support the weights of the
rack and the outdoor unit.
Install the rack close to the column as much as
possible.
Step 3.2 Connecting the power
and communication cables and the

refrigerant pipes

L1
L2
Outdoor-to-indoor power
Power cable
cable (three wires)
(three wires)
CAUTION
Be sure to fix the power cables and communication
cable with a cable clamp.
F1
F2
Communication cable
(two wires)