Setup Menus For Ps Data; Communication Setup (Ps Data); System Setup (Ps Data) - Panasonic WJ-MP204C Operating Instructions Manual

Data multiplex unit
Hide thumbs Also See for WJ-MP204C:
Table of Contents

Advertisement

Setup Menus for PS
Communication setup (PS
Communication parameters for a PS
are set in this menu.
1. Hold down the SETUP button for 2 seconds to open the
setup menu.
WJ-MP204C SETUP MENUX.XX
COMMUNICATION
SYSTEM
2. Move the cursor to COMMUNICATION
SET. The communication setup appears.
COMMUNICATION
UNIT ADDRESS 1
BAUD RATE
DATA BIT
PARITY CHECK NONE
STOP BIT
WAIT TIME
8 UNIT ADDRESS
1. Move the cursor to UNIT ADDRESS, then specify a
number with the [–] or [+] button. The default setting is
1.
Available numbers: 1-99
Note: This setting takes effect only when the UNIT
switch is set to 0 on the front panel.
BAUD RATE
1. Move the cursor to BAUD RATE, then specify a rate
with the [–] or [+] button. The default setting is 9 600.
Available rates (bit per second): 19 200, 9 600,
4 800, 2 400
21
Data
Data)
Data protocol system
, then press
9600
8
1
OFF
DATA BIT
1. Move the cursor to DATA BIT, then specify a bit length
with the [–] or [+] button. The default setting is 8.
Available bit length: 7, 8
PARITY
1. Move the cursor to PARITY CHECK, then specify a
check mode with the [–] or [+] button. The default set-
ting is NONE.
Available check modes: NONE, EVEN, ODD
STOP BIT
1. Move the cursor to STOP BIT, then specify a bit length
with the [–] or [+] button. The default setting is 1.
Available bit length: 1, 2
WAIT TIME
The unit will retransmit data when there is no response dur-
ing the specified wait time.
1. Move the cursor to WAIT TIME, then specify a time with
the [–] or [+] button. The default setting is OFF for not
resending.
Available wait times (ms): OFF, 100, 200, 400,
1 000
2. Press ESC to return to the WJ-MP204C SETUP MENU.
System setup (PS
Parameters related to alarm, sync, and remote functions
are set in this menu for a PS
The SYSTEM menu is displayed when you select it in the
WJ-MP204C SETUP MENU.
SYSTEM
ALARM MODE
COMP/VD2/DATA
VS/VD INPUT
CAMERA CONFIG
DAISY MODE
TERMINAL
Data)
Data protocol system.
ON
VD
ON
ALARM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents