Fujitsu PRIMERGY CX400 M1 System Configurator And Order-Information Manual page 24

Table of Contents

Advertisement

K1
CX25y0 M1
SATA Disk Drive 2.5"
HDD SATA 6Gb/s 2.5" with hot plug/hot replace tray
250GB 7.2krpm,<9,5ms, 64MB Cache
500GB 7.2krpm,<9,5ms, 64MB Cache
1TB 7.2krpm,<9,5ms, 64MB Cache
2TB 7.2krpm,<9,5ms, 128MB Cache
max. 2/6x per server node
Enterprise Solid State Disk, Mainstream Endurance*
SSD SATA 6Gb/s 2.5" with hot plug/hot replace tray
100GB, Mainstream Performance
200GB, Mainstream Performance
400GB, Mainstream Performance
800GB, Mainstream Performance
max. 2/6x per server node
Read intensive Solid State Disk, Entry Endurance*
SSD SATA 6Gb/s 2.5" with hot plug/hot replace tray
120GB
240GB
480GB
800GB
max. 2/6x per server node
SAS Disk Drive 2.5"
HDD SAS 6Gb/s 2.5" with hot plug/hot replace tray
300GB 10000rpm,<4,5ms, 64MB Cache, SAS 6G
450GB 10000rpm,<4,5ms, 64MB Cache, SAS 6G
600GB 10000rpm,<4,5ms, 64MB Cache, SAS 6G
900GB 10000rpm,<4,5ms, 64MB Cache, SAS 6G
1,2TB 10000rpm,<5,0ms, 64MB Cache, SAS 6G
146GB 15krpm,<3,1ms, 32MB Cache, SAS 6G
300GB 15krpm,<2,95ms, 64MB Cache, SAS 6G
450GB 15krpm,<2,95ms, 64MB Cache, SAS 6G
600GB 15krpm,<2,95ms, 64MB Cache, SAS 6G
HDD SAS 12Gb/s 2.5" with hot plug/hot replace tray
300GB 10000rpm, 128MB Cache, SAS 12G, 512n
600GB 10000rpm, 128MB Cache, SAS 12G, 512n
900GB 10000rpm, 128MB Cache, SAS 12G, 512n
1.2TB 10000rpm, 128MB Cache, SAS 12G, 512n
max. 2/6x per server node
Enterprise Solid State Disk, Mainstream Endurance*
SSD SAS 12Gb/s 2.5" with hot plug/hot replace tray
400GB, Enterprise Performance
800GB, Enterprise Performance
max. 2/6x per server node
SSD Interface: SAS12Gb/s and SAS 6Gb/s.
For 12G support is an SAS 12G controller required
PCIe Solid State Disk, Mainstream Endurance*
SSD PCIe
Gen3 2.5" with hot plug/hot replace tray
800GB
2x
1.6TB
2.0TB
max. 2 per server node w/ Type B drive bay option
L
Fujitsu Technology Solutions x86 PRIMERGY Server
System configurator and order-information guide
PRIMERGY CX400 M1
S26361-F3895-E250
S26361-F3895-E500
S26361-F3895-E100
S26361-F3936-E200
S26361-F3821-E100
S26361-F3821-E200
S26361-F3821-E400
S26361-F3821-E800
Liquid cooling is not possible
S26361-F5525-E120
S26361-F5525-E240
S26361-F5525-E480
S26361-F5525-E800
Liquid cooling is not possible
S26361-F5537-E130
S26361-F5537-E145
S26361-F5537-E160
S26361-F5537-E190
S26361-F5537-E112
S26361-F5538-E514
S26361-F5538-E530
S26361-F5538-E545
S26361-F5538-E560
S26361-F5550-E130
S26361-F5550-E160
S26361-F5550-E190
S26361-F5550-E112
Liquid Cooling is not possible
S26361-F5298-E400
S26361-F5298-E800
S26361-F5534-E800
S26361-F5534-E161
S26361-F5534-E201
Status 2016-10-31
Restriction for air cooling
Amb
#HDD/ #SATA #PCIe
CPU
Temp
SSD
DOM
≥135W
30C
2
1
≤ 120W
35C
6
1
≥135W and ≤120W can't be mixed under same chassis
*) SSD Mainstream Endurance
10DWPD over 5y
*) SSD Mainstream Endurance
0.3DWPD over 5y
*) SSD Mainstream Endurance
10DWPD over 5y
*) SSD Mainstream Endurance
xxDWPD over 5y
2
2
SATA
SAS
PCIe
24 of 33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents