14. Go to "Restoring environment variables on the CompactFlash card" on page
Placing system files on the CompactFlash card using a PC and card
reader/writer
10. Plug the target node power supplies into the power source and turn them on.
11. Press Ctrl-C during reboot at the message: Press Ctrl-C for the Special
12. Select 1 from the Special Boot Menu to boot the node normally.
13. Check the status of the cluster by entering the following command: cf status
14. Download the system files to the CompactFlash card by entering the following
38
IBM System Storage: N7000 Series Hardware and Service Guide
39
1. Copy the bootable kernel image (the appropriate rlse_setup.exe file, where
<rlse> is the Data ONTAP release) to your system. Copy the boot image from
the boot directory at /etc/boot/netapp-x86-64, or download it from the IBM
N series support website, which is accessed and navigated as described in
"Websites" on page xx. On the IBM N series support website, the Data
ONTAP Matrix provides a current list and history of Data ONTAP releases
available by release family and supported storage systems.
Contact technical support if you cannot get a boot image from these sources.
Make sure that you download the file designed for administering for a PC
and that it is the correct release of Data ONTAP for your system.
2. Insert the CompactFlash card into the CompactFlash card reader. The
CompactFlash card is pre-formatted. Do not format the CompactFlash card.
3. Extract the contents of the rlse_setup.exe file to a temporary folder on your
PC.
4. Create a folder called x86_64 in the root partition of the CompactFlash card,
and then create a subfolder called KERNEL in the x86_64 folder.
5. Move the bootable kernel image into the KERNEL folder in Windows Explorer.
The bootable kernel image is called netapp_<rlse>-x86-64. It is located on
your PC in the boot folder in the files you extracted from rlse_setup.exe.
6. Rename the netapp_<rlse>-x86-64 image to Primary.KRN.
7. While grounded, install the CompactFlash card with the kernel image in the
controller LCD module. Make sure it is firmly seated in the LCD module.
8. Flip the ejector level down on the LCD module so that it is lying flat, and
then reinstall the bezel.
9. Enter the following command from the partner node's console: cf giveback
-f
Boot Menu
command from the prompt: download
v If the download is successful, the following message is displayed on the
console: Operator requested download completed.
v If the download fails, the following message is displayed on the console:
Failed to open download script file /etc/boot/x86-64/kernel_1024.cmds:
No such file [download.requestDoneError:error]: Operator requested
download failed.
Complete the following substeps to correct this error:
a. Run the software install command by entering the following command:
software install url -f where url is the location of the setup.exe
command.