To do...
Stop running the specified patches
Delete the specified patches from
the memory patch area
Displaying and maintaining the software upgrade
To do...
Display information about the boot
file
Display the patch information
Software upgrade configuration examples
Unless otherwise noted, devices in the configuration examples are operating in non-FIPS mode.
Immediate upgrade configuration example
Network requirement
As shown in
•
member ID of 1 and the slave switch with the member ID of 2.
The current software version is soft-version1 for the IRF virtual device. Upgrade the software version
•
of the IRF virtual device to soft-version2 and configuration file to new-config.
•
The latest application soft-version2.bin and the latest configuration file new-config.cfg are both
saved on the TFTP server.
The IP address of the IRF virtual device is 1.1.1.1/24, the IP address of the TFTP server is 2.2.2.2/24,
•
and the TFTP server and IRF virtual device can reach each other.
Use the command...
patch deactive patch-number slot
slot-number
patch delete patch-number slot
slot-number
Use the command...
display boot-loader [ slot
slot-number ] [ | { begin | exclude
| include } regular-expression ]
display patch information [ |
{ begin | exclude | include }
regular-expression ]
Figure
38, the IRF virtual device comprises two member devices, the master with the
129
Remarks
Required
When you stop running a patch,
the patch state becomes
DEACTIVE, and the system runs in
the way before it is installed with
the patch.
Required
Deleting patches only removes the
patches from the memory patch
area, and does not delete them
from the storage medium. The
patches turn to IDLE state after this
operation. After a patch is deleted,
the system runs in the way before it
is installed with the patch.
Remarks
Available in any view
Available in any view