Playback Servo Check; 30 Pg Pulse Position Check - Sony AV-3600 Service Manual

Table of Contents

Advertisement

Adjust
for:
Minimum
lock-in
time
when
the
Videocorder
is
set
to
the
REC/E-E
mode
from
a
complete
stop.
Test Point/
Board:
TP-406/SV
(CTL
puise
output)
Check:
Waveforms
in Fig. 6-6.
TP-406
1
^—
...
m
1f?
fi
mr
m
15
±2
V
m
/O.O fDS
*\
Fig.
6-5.
Servo response-time adjustment
Fig. 6-6.
Control
track
pulse
check
Adjustment/
Board:
Signal
Source:
Equipment
Required:
Procedure:
R451/SV
(Servo
Response Time)
Telecast
signal
(1)
Oscilloscope
(2)
TV
monitor
Adjustment:
Signal
Source:
None
Telecast Signal
1
.
Set
up
the E-to-E
mode
using
a telecast
signal.
2.
Connect
the scope to
TP-410.
Set
the time
base to
5
msec/ cm.
3.
Set the
Function
Lever
to
STOP
(release
the
RECORD
button)
and
wait
until
the
rotating
head
stops turning completely.
Then,
depress the
RECORD
button.
Observe
the
waveform on
the scope.
The
PG
pulse
will
move
up
and
down
a
few
times
and
then lock
on
the
30
Hz
multivibrator
ramp
as
shown
in
Fig. 6-5.
4.
Adjust
R451
for
minimum
lock-in
time without
hunting.
Repeat
Step
3
after
each adjustment
ofR451.
Note:
Clockwise
rotation
of
R451
shortens the
lock-in
time,
but
increases
hunting.
Counterclockwise
rotation
decreases
hunting but lengthens
lock-in time.
6-7.
PLAYBACK SERVO CHECK
Check
that
the
correct
CTL
(Control
track) pulses
are
reproduced
for the servo
system
in
the
Playback
mode.
Equipment
Required:
(1)
Oscilloscope
(2)
TV
monitor
Procedure:
1.
Make
a
recording of
a
telecast
signal.
2.
Play
back
the
tape.
3.
Connect
the scope to
TP-406 and
check
the
waveform shown
in Fig. 6-6.
4.
Confirm
that
the
picture locks
up
correctly
in
the Playback
mode.
If
the servo
system
does
not
stabilize,
troubleshoot the
CTL
pulse
amplifying
circuits.
The
following adjustments
in Sees.
6-8
and &9 are
necessary
only
when
either
one of
30
PG
coils
Has
been
replaced or repositioned.
6-8.
30
PG
PULSE
POSITION
CHECK
(30
PG
Coil Position)
Correct
coil
positions
ensure proper switching
between
video heads,
and
also
ensure
switching
at
the
proper time with
respect to
vertical
sync.
CAUTION
Avoid
adjustment of
30
PG
coils
unless
tests
indicate that
adjustment
must
be made.
Test Point/
Board:
TP-304/V1
(Video
signal output)
6-4