Vertical Sync Former Check - Sony AV-3600 Service Manual

Table of Contents

Advertisement

5.
If
it
does
not,
change
R007
from 100
k£2
to
200
k£2.
6-13.
VERTICAL SYNC FORMER CHECK
Test
Point:
6-Pin
CAMERA
Receptacle
Check:
Waveform shown
in Fig.
6-13.
Adjustmen
t:
None
Signal
Source:
None
required
Equipment
Required:
Oscilloscope
Procedure:
1.
Turn
on
the
Videocorder with
or
without an
input
signal.
2.
Connect
a
75-ohm
resistor
between
Pin 2
and
Pin 6
of
the
6-pin
CAMERA
receptacle.
3.
Connect
the scope to Pin
2.
4.
Check
that the
output
is
as
shown
in Fig.
6-13.
5.
If
it
is
not,
check and
troubleshoot the
SY3
Board
mounted
behind
the
connector
panel.
75n
Vo'
*o\
u^°
)
V?
°J
^
^o^y
CAMERA
receptacle
7
±4H
±1
m
more
than
2V(p-p)
T
b
L
Fig.
6-
13.
Vertical
sync
for
camera
6-8