Figure 15: Serial DB9 Port
a
No internal termination is provided.
b
The Common terminal is optically isolated. However, there is transient voltage protection circuitry between the Common terminal and chassis ground.
c
Connected internally.
d
In RS232 mode, this pin enters a high impedance state. A DTE that asserts RTS will see CTS asserted, although the device will not perform hardware flow
control.
8
Figure 16: Serial RJ45 Port
e
No internal termination is provided.
f
Connected internally.
g
In RS232 mode, this pin enters a high impedance state. A DTE that asserts RTS will see CTS asserted, although the device will not perform hardware flow
control.
16
5
1
9
6
1
a
Pin
RS232 Mode
1
DCD
2
TX
3
RX
4
DTR
5
Common (Isolated Ground)
6
DSR
cd
7
CTS
cd
8
RTS
9
RI (No
Connection)
Shield
Chassis Ground
e
Pin
RS232 Mode
f
1
DSR/RI
f
2
DCD
3
DTR
4
Common (Isolated) Ground
5
RX
6
TX
fg
7
CTS
g
8
RTS
Shield
Chassis Ground
RUGGEDCOM RS910
Installation Guide
RS485 Mode
RS422 Mode
TX/RX+
TX+
RX+
b
RX-
TX/RX-
TX-
RS485 Mode
RS422 Mode
RX-
RX+
TX/RX+
TX+
TX/RX-
TX-