Carrier 58MVP Troubleshooting Manual page 42

Variable-speed 2-stage electronic condensing furnace

Advertisement

Furnace:
Model Number
Serial Number
Position? U/F D/F H/R H/L
Outdoor Unit:
Model Number
Serial Number
What type of media filter is being used?
What is static pressure drop across filter?
Does fault code go away when you remove filter?
What Zone System is applied?
What Zone has highest total ESP?
Is a Zone Bypass Damper being used?
What type of Bypass Humidifier is being used?
Is Bypass Humidifier setup switch on or off?
If you have a Fault Code 41 and/or 44, do the following:
1. Turn power off to furnace and outdoor unit.
2. Set A/C setup switch for 2 tons (800 CFM).
3. Turn only power to furnace back on.
4. Set thermostat for a call for cooling.
5. Check supply and return ESP as in Appendix E. Add these 2 ESP readings together for Total ESP. Repeat these steps until a fault code
flashes on the microprocessor. Log your information on this sheet.
• At Low Heat:
Supply ESP
Return ESP
Any Fault Code Flashing? If so what number?
• At High Heat:
Supply ESP
Return ESP
Any Fault Code Flashing? If so what number?
• At 2 Ton A/C Setting:
Supply ESP
Return ESP
Any Fault Code Flashing? If so what number?
• At 2.5 Ton A/C Setting:
Supply ESP
Return ESP
Any Fault Code Flashing? If so what number?
• At 3 Ton A/C Setting:
Supply ESP
Return ESP
Any Fault Code Flashing? If so what number?
• At 3.5 Ton A/C Setting:
Supply ESP
Return ESP
Any Fault Code Flashing? If so what number?
• At 4 Ton A/C Setting:
Supply ESP
Return ESP
Any Fault Code Flashing? If so what number?
• At 5 Ton A/C Setting:
Supply ESP
Return ESP
Any Fault Code Flashing? If so what number?
Duct Static Check Sheet
At what CFM?
and is it operating (opening)
(Before or After Evaporator Coil)
(Before or After Filter)
(Before or After Evaporator Coil)
(Before or After Filter)
(Before or After Evaporator Coil)
(Before or After Filter)
(Before or After Evaporator Coil)
(Before or After Filter)
(Before or After Evaporator Coil)
(Before or After Filter)
(Before or After Evaporator Coil)
(Before or After Filter)
(Before or After Evaporator Coil)
(Before or After Filter)
(Before or After Evaporator Coil)
(Before or After Filter)
42
Indoor Coil:
Model Number
Serial Number
Thermostat
Electronic Air Cleaner