CONDITION
No sound.
No sound one channel.
Weak bass/di used stereo image.
Remote control handset not working.
Standby LED turns red during operation.
POSSIBLE CAUSES
Power AC lead unplugged or power not
switched ON.
Tape Monitor selected.
Mute on.
Rear Pre-out/Main-in amp links not tted.
Balance control not centered.
Speaker not properly connected or damaged.
Input lead disconnected or damaged.
Speakers wired out of phase.
Battery at or incorrectly inserted.
IR transmitter or receiver windows obstructed.
IR receiver in direct sun or very bright ambient
light.
C 375BEE has overheated.
Overall impedance of loudspeakers too low.
REFERENCE

TROUBLESHOOTING

POSSIBLE SOLUTIONS
Check if AC lead is plugged in and power
switched ON.
De-select Tape Monitor mode.
Switch o Mute.
Fit links.
Center Balance control.
Check connections and speakers.
Check leads and connections.
Check connections to all speakers in the
system.
Check or replace battery.
Remove obstruction.
Place unit away from direct sun, reduce
amount of ambient light.
Turn C 375BEE OFF; make sure ventilation
slots on top and bottom of C 375BEE are not
blocked. After C 375BEE has cooled down,
turn back ON.
Ensure the overall loudspeaker impedance is
not below 4 ohms.
13