4.2.7 Linear Scale

When you hold the Linear Scale, hold its ends or two points of
C A U T I O N
the top and bottom surfaces with your hands; do not touch the
reading surface.
Take care that the reading surface is not soiled or scratched.
Especially when passing the Linear Scale through the CR
Encoder during reassembly work, take great care that grease of
the CR Guide Shafts does not adhere to the reading surface.
About 25mm
Hold here
Hold here
C H E C K
If you need to move the Carriage Unit, unlock the Carriage in
P O I N T
advance.
(See
4.1.5 How to Unlock the Carriage
1.
Remove the Panel Assy (p.63)
2.
Remove the Scanner Unit (p.65)
3.
Remove the Main Board Assy / Case Open Sensor (p.66)
4.
Remove the Waste Ink Tray Assy (p.69)
5.
Remove the Middle Housing Assy (p.70)
6.
Remove the spring from the left frame of the printer. (Fig. 4-36)
7.
Release the Linear Scale from the hook at the right frame of the printer.
8.
Pull out the Linear Scale from the CR Encoder of the Carriage Assy.
9.
Turn the Linear Scale upward by 90 degrees and release it from the left hook.
Disassembly and Assembly
About 45mm
Hold here
Hold here
CR_Scale02.eps
(p.61))
Removal of Exterior Parts
6. Remove the spring
9. Turn it by 90 degrees and release it
Figure 4-36. Removing the Linear Scale
Install the Linear Scale with the cut portion upward.
Revision B
7. Release it from the hook
Carriage Assy
8. Pull it through the CR Encoder
Cut portion