Technical specifications
8.4 XR-300M technical specifications
Table 8- 40
Device version
(power supply)
2 x 24 VDC
1 x 100 to 240 VAC
8.4.3

Cable lengths

Table 8- 41
Cable type
IE TP torsion cable
IE FC TP Marine Cable
IE FC TP Trailing Cable
IE FC TP Flexible Cable
IE FC TP standard cable
Table 8- 42
Cable type
IE FC Standard Cable, 4 × 2, 24
AWG
IE FC Flexible Cable, 4 × 2, 24
AWG
IE FC Standard Cable, 4 × 2, 22
AWG
IE FC Flexible Cable, 4 × 2, 22
AWG
Note
Permitted cable lengths (fiber-optic cable - Fast Ethernet or gigabit)
The values correspond to those of the permitted MM900 media modules and SFP
transceivers.
172
Plug-in terminal block for connectors of the power supply and signaling contact
Power supply
2 x 4-pin
1 x 2-pin
Permitted cable lengths (copper cable - Fast Ethernet)
Accessory (plug, outlet,
TP cord)
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC RJ-45 Plug 180
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC RJ-45 Plug 180
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC RJ-45 Plug 180
Permitted cable lengths (copper cable - gigabit Ethernet)
Accessory (plug, outlet,
TP cord)
with IE FC RJ-45 Plug 180,
4 × 2
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC Outlet RJ-45
+ 10 m TP cord
Signaling contact
2 x 2-pin
1 x 2-pin
Permitted cable length
0 to 45 m
+ 10 m TP cord
0 to 55 m
0 to 75 m
+ 10 m TP cord
0 to 85 m
0 to 90 m
+ 10 m TP cord
0 to 100 m
Permitted cable length
0 to 90 m
0 to 60 m
+ 10 m TP cord
0 to 90 m
+ 10 m TP cord
Operating Instructions, 02/2012, A5E01113043-12