Troubleshooting
Push the safety plate out of the way (fig. 78, item 1).
Turn air suction tube and pull off from below.
Swivel the "CombiVENT" gas combination unit forward
(fig. 79, item 1)
Remove the "CombiVENT" gas combination unit from its
bayonet connector and pull upwards to detach (fig. 79,
item 2).
Loosen the three screws (fig. 80).
Screw the air suction tube safety plate into place (not
supplied with new gas burner fitting).
Subject to modifications resulting from technical improvements!
Servicing manual for wall-mounted condensing gas boiler 600 Series 11S/19S/24S/24C • Issued 02/2006
Fig. 78 Replacing the gas burner fitting on the 600 Series:
Remove the
air suction tube
2
Fig. 79 Replacing the gas burner fitting on the 600 Series:
Remove the gas connection unit
2
Fig. 80 Replacing the gas burner fitting on the 600 Series:
Replace the gas burner fitting
Buderus Ltd. • http://www.buderus-domestic.co.uk
1
1
1
3
61