Product Documentation Online ..................................................................... 2
Upgrading a Unit to the Advanced SLM Feature Set .................................... 2
Package Checklist ......................................................................................... 2
Preparation ................................................................................................... 3
Cables You May Need to Order .................................................................... 3
Safety Instructions ........................................................................................ 4
Installing the Power Supply and Cord ........................................................... 4
Connecting to an Asynchronous Terminal or PC .......................................... 5
Verifying that Self-Test Passed ..................................................................... 5
Menu Hierarchy ............................................................................................. 6
A Quick Guide to Configuration .................................................................... 9
Full Installation and Setup ............................................................................ 10
About the Installation Procedures ................................................................. 10
Setting Up Local Management at the Central Site ........................................ 14
Automatic Configuration ................................................................................ 14
Connecting to the Network ........................................................................... 15
Configuring SNMP Trap Managers and Traps .............................................. 16
Verifying the End-to-End Path ....................................................................... 16
Connecting to the Ethernet ........................................................................... 17
Connecting to the DTE (Router or FRAD) .................................................... 18
Verifying That Data is Being Received .......................................................... 19
Checking PVC Connections .......................................................................... 19
Important Safety Instructions ....................................................................... 20
EMI Notices .................................................................................................. 21
Government Requirements ........................................................................... 21
Warranty, Sales, Service, and Training Information ...................................... 24
Document Feedback ..................................................................................... 24
Trademarks ................................................................................................... 24
Patent Notification ......................................................................................... 24
1

Advertisement

Table of Contents
loading

Summary of Contents for Paradyne FrameSaver 9123

  • Page 1: Table Of Contents

    ® FrameSaver 9123 Router Installation Instructions Document Number 9123-A2-GN11-00 March 2003 Contents Product Documentation Online ..............2 Upgrading a Unit to the Advanced SLM Feature Set ........2 Package Checklist ..................2 Preparation ....................3 Cables You May Need to Order ..............3 Safety Instructions ..................
  • Page 2: Product Documentation Online

    FrameSaver SLV Operations Guide (9000-A2-GB33) FrameSaver SLV Router Command Line Interface (9000-A2-GB34) To order a paper copy of a Paradyne document, or to speak with a sales representative, please call 1-727-530-2000. Upgrading a Unit to the Advanced SLM Feature Set Full Service Level Management (SLM) capability can be activated in units that have the basic diagnostic feature set at any time.
  • Page 3: Preparation

    Preparation Make sure you have: ❑ A dedicated, grounded power outlet that is protected by a circuit breaker within 6 feet of the FrameSaver unit ❑ A clean, well-lit, and ventilated site that is free from environmental extremes ❑ One to two feet of clearance for cable connections ❑...
  • Page 4: Safety Instructions

    Safety Instructions Important Safety Instructions Please refer to the on page 19. Installing the Power Supply and Cord Procedure 1. Insert the power cord’s plug into the POWER jack. Grounded Power Outlet ETHERNET POWER 9123-C FrameSaver FrameSaver FLEX ® System System Network Port...
  • Page 5: Connecting To An Asynchronous Terminal Or Pc

    Connecting to an Asynchronous Terminal or PC A VT100-compatible asynchronous terminal or a PC providing VT100 terminal emulation must be used to set up access to and management of the unit. Procedure 1. Configure the terminal or PC so it is compatible with the FrameSaver unit: —...
  • Page 6: Menu Hierarchy

    Menu Hierarchy The Menu Hierarchy shows the organization of the FrameSaver unit’s screens. Support for all features may not be available in the firmware release you are running. Status System and Test Self-Test Results Status Last Reset Health and Status Test Status LMI Reported DLCI...
  • Page 7: Configuration System

    Test Network PVC Tests PVC Loopback Send Pattern Monitor Pattern Network Physical Local Line Loopback Tests Local Payload Loopback Remote Send Line Loopback Send Pattern Monitor Pattern IP Ping Lamp Test Abort All Tests Configuration System Frame Relay and LMI Class of Service Definitions Service Level Verification General...
  • Page 8 Control System Device Name Information System Name, Location, Contact Date Time Administer Logins Login ID Password Access Level Change Operating Back-to-Back Mode Mode Standard Mode Select Software Current Release Release Alternate Release Switch & Reset LMI Packet Capture Interface Capture Utility Packet Capture Start/Stop Status Packets in Buffer...
  • Page 9: A Quick Guide To Configuration

    A Quick Guide to Configuration The FrameSaver unit should operate using the default (factory-set) configuration options, with exception to the changes specified in these installation instructions. Refer to the following table for help in navigating through the menus. Press the . . . To .
  • Page 10: Full Installation And Setup

    About the Installation Procedures There are two methods for installing and setting up the FrameSaver unit. One person can install and set up the unit. If this is the case, see Full Installation and Setup An installer can physically install and set up access to the unit, and the network Minimal operation center (NOC) can complete the setup.
  • Page 11 3. Enter the Node IP Address and Subnet Mask. 4. Set TS Access to DLCI, then select a DLCI on the network interface that will be used for the troubleshooting access link. 5. Create a Dedicated Network Management Link, selecting a DLCI for the management link at the Which DLCI would you like to Create a Dedicated Network Management Link on? prompt, which will be used by the NOC to access the unit.
  • Page 12: Minimal Installation For Service Providers (Leased Line Mode)

    Minimal Installation for Service Providers Verify with your service provider that frame relay service is turned on at the site. Follow Step 1 through Step 10 Full Installation and Setup on page 10. Physical installation of the unit is complete; the NOC can now remotely access the unit for additional configuration.
  • Page 13: Setting Up Local Management At The Central Site

    Setting Up Local Management at the Central Site Procedure 1. Create a DLCI for the virtual router port. Configuration Virtual Router Ports DLCI Records 2. Save the configuration. 3. Create a Management PVC using the virtual router port DLCI just created. Configuration Management and Communication Management PVC...
  • Page 14: Automatic Configuration

    Automatic Configuration The FrameSaver unit provides several automatic configuration features. Frame Relay Discovery and configuration is one of these features. Main Menu Auto-Configuration The default discovery mode is 1PPort. In this mode: Auto-Configuration is enabled on the virtual router port. A virtual router port DLCI is created for each network DLCI and automatically cross-connected to it.
  • Page 15: Connecting To The Network

    Connecting to the Network Now that the FrameSaver unit is set up, the unit can be connected to the network. Procedure 1. Insert the 8-pin connector of the RJ48C network cable into the network interface. 2. Insert the other end of the cable into the RJ48C modular jack. RJ48C Jack ETHERNET...
  • Page 16: Configuring Snmp Trap Managers And Traps

    Configuring SNMP Trap Managers and Traps Once the FrameSaver unit is connected to the network, SNMP trap managers and SNMP traps can be configured. Procedure To enter SNMP managers and configure traps: 1. Select SNMP Traps. Main Menu Configuration Management and Communication SNMP Traps 2.
  • Page 17: Connecting To The Ethernet

    Connecting to the Ethernet Procedure 1. Insert one 8-pin connector of the Ethernet cable into the Ethernet port. 2. Insert the other end of the cable into the Ethernet interface of the LAN where the NMS resides. ETHERNET POWER 00-16687 3.
  • Page 18: Verifying That Data Is Being Received

    Verifying That Data is Being Received Procedure 1. Return to the Main Menu. 2. Select Performance Statistics, and select an interface’s frame relay statistics. Main Menu Status Performance Statistics Frame Relay Net1-FR1 3. Verify that the Frames Received and Characters Received counts under the Frame Relay Link statistics are incrementing, and there are no errors under the Frame Relay LMI statistics.
  • Page 19: Important Safety Instructions

    Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered.
  • Page 20: Emi Notices

    The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne. CANADA – EMI NOTICE: This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment regulations.
  • Page 21 United States Notice to Users of the Telephone Network This equipment complies with Part 68 of the FCC rules. On the bottom of the housing is a label that contains, among other information, the FCC registration number for this equipment. If requested, please provide this information to your telephone company. If your unit causes harm to the telephone network, the telephone company may discontinue your service temporarily.
  • Page 22 Canada Notice to Users of the Canadian Telephone Network The Industry Canada label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user’s satisfaction.
  • Page 23: Warranty, Sales, Service, And Training Information

    Document Feedback We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to userdoc@paradyne.com. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional clarification.
  • Page 24 *9123-A2-GN11-00* *9123-A2-GN11-00*...

Table of Contents