5.1
Both Sides Adjustment
G
Measure the gap between the front and
back sides at each point of [a] to [d] on
the [back] side of the printed out chart.
-
This figure shows an example to measure [a].
The scale resolution is 0.5 mm.
-
In this figure, the black line indicates the front
side, and the blue line indicates the back
side.
-
The measurement value can be entered in
units of up to 0.1 mm.
-
For example, as shown in the figure, if the
scale of [a] is misaligned 1.5 mm in the plus
side compared with the front side, press [1] -
[5] - [+/-] to enter "-1.5" as the adjustment
value. Then, the blue line on the back side
will be moved 1.5 mm toward the minus side.
-
Write down the measured values so that you
do not forget them.
H
Press [a] to [d] of each point, and enter the adjustment value using the keypad, [,], or
[+] on the screen.
-
If the printing position is misaligned to the minus (-) side, enter a positive value (+). If the printing
position is misaligned to the plus (+) side, enter a negative value (-).
-
To reset a numeric value, press [Clear].
-
To switch the positive sign (+) and negative sign (-), press [+/-].
5-12