Bq060 Cooling Capacities (5 Ton) - York Sunline 2000 BQ 036 Technical Manual

Single package heat pump units
Table of Contents

Advertisement

254595-YTG-C-0308
TABLE 5: BQ060 COOLING CAPACITIES (5 TON)
AIR ON
EVAPORATOR
TOTAL
COIL
1
CAP.
INPUT
MBH
CFM
WB °F
72
68
67
65
2500
62
61
57
60
72
67
67
64
2250
62
60
57
59
72
66
67
63
2000
62
59
57
58
72
64
67
61
1750
62
57
57
57
72
62
67
59
1500
62
55
57
55
AIR ON
EVAPORATOR
TOTAL
COIL
1
CAP.
INPUT
MBH
CFM
WB °F
72
64
67
59
2500
62
54
57
54
72
63
67
58
2250
62
53
57
53
72
62
67
57
2000
62
52
57
52
72
60
67
55
1750
62
50
57
50
72
57
67
53
1500
62
48
57
48
1. These capacities are gross ratings. For net capacity, determine the kW of the supply air blower motor from the SUPPLY AIR BLOWER PERFORMANCE
Table, multiply this value by 3.415 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit.
2. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input
is 0.35kW. Refer to the SUPPLY AIR BLOWER PERFORMANCE Table for the kW of the supply air blower motor.
NOMINAL RATING
Johnson Controls Unitary Products
TEMPERATURE OF AIR ON CONDENSER COIL
85°F
SENSIBLE CAPACITY
POWER
ENTERING DRY BULB, °F
2
kW
86
83
80
77
5.7
51
44
38
31
5.6
58
56
50
43
5.6
61
61
59
53
5.5
60
60
59
53
5.6
48
42
36
30
5.6
57
54
48
42
5.5
60
60
57
51
5.5
59
59
58
52
5.6
45
40
34
29
5.5
56
51
45
40
5.4
59
59
55
50
5.4
58
58
57
52
5.5
42
37
32
27
5.5
52
47
42
37
5.4
57
56
51
46
5.4
57
57
53
48
5.5
38
34
30
25
5.5
48
43
39
35
5.4
55
52
47
43
5.3
55
54
49
45
TEMPERATURE OF AIR ON CONDENSER COIL
105°F
SENSIBLE CAPACITY
POWER
ENTERING DRY BULB, °F
2
kW
86
83
80
77
6.0
51
44
38
31
5.9
51
51
49
42
5.9
54
54
51
46
5.8
54
54
52
46
5.9
48
42
36
30
5.9
51
51
46
40
5.8
53
53
52
46
5.8
53
53
52
46
5.9
45
39
34
28
5.9
51
49
44
38
5.8
52
52
51
46
5.7
52
52
51
46
5.9
41
37
32
27
5.8
48
46
41
36
5.7
50
50
48
43
5.7
50
50
48
43
5.8
38
34
30
25
5.8
47
43
38
34
5.7
48
48
45
41
5.6
48
48
45
41
1
TOTAL
POWER
1
CAP.
INPUT
MBH
74
71
68
-
-
-
67
6.0
37
30
-
64
5.9
46
39
33
59
5.9
47
40
33
58
5.8
-
-
-
66
5.9
36
30
-
63
5.9
45
39
33
57
5.8
46
40
34
57
5.8
-
-
-
65
5.9
35
29
-
61
5.9
44
39
33
56
5.8
46
41
36
56
5.7
-
-
-
62
5.9
33
28
-
59
5.8
41
37
32
54
5.7
44
39
34
54
5.7
-
-
-
60
5.8
31
26
-
57
5.8
39
35
30
52
5.7
41
37
32
52
5.6
1
TOTAL
POWER
1
CAP.
INPUT
MBH
74
71
68
-
-
-
60
6.9
36
29
-
54
6.6
40
33
26
49
6.5
41
33
26
49
6.5
-
-
-
60
6.8
34
28
-
54
6.6
40
34
28
49
6.5
41
35
27
49
6.4
-
-
-
59
6.8
33
27
-
53
6.5
40
35
30
48
6.4
40
36
31
47
6.4
-
-
-
56
6.7
31
26
-
51
6.5
39
34
29
46
6.4
39
34
30
45
6.3
-
-
-
53
6.6
30
26
-
48
6.4
37
32
28
44
6.3
38
32
28
43
6.2
95°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
kW
86
83
80
77
74
51
45
38
31
56
56
50
43
37
59
59
57
50
44
58
58
57
51
44
48
42
36
30
55
54
48
42
35
57
57
55
50
44
57
57
56
50
45
45
40
34
29
55
51
45
40
34
56
56
54
49
44
56
56
55
50
44
43
38
33
28
53
48
44
39
34
54
54
52
48
43
54
54
53
49
43
41
36
32
28
51
46
42
38
34
52
52
50
46
42
52
52
51
47
42
115°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
kW
86
83
80
77
74
50
43
37
30
54
53
47
41
34
49
49
48
42
35
49
49
49
43
35
47
41
35
29
47
47
45
39
32
49
49
47
42
36
49
49
48
43
37
44
38
33
27
45
45
42
36
31
48
48
46
42
36
47
47
46
43
36
40
35
30
25
43
43
38
33
29
46
46
43
38
33
45
45
43
38
33
36
31
27
23
41
39
35
30
26
44
44
39
35
30
43
43
40
36
30
1
71
68
-
-
-
30
-
38
31
39
32
-
-
-
29
-
38
32
39
33
-
-
-
29
-
38
33
39
34
-
-
-
29
-
38
33
39
34
-
-
-
29
-
38
34
39
35
1
71
68
-
-
-
27
-
28
22
28
23
-
-
-
26
-
30
24
31
25
-
-
-
26
-
31
25
32
25
-
-
-
24
-
28
24
28
25
-
-
-
22
-
26
22
26
23
11