7-3 SPECIFICATIONS FOR FIELD SUPPLIED FUSES AND WIRE
Model
CS-20KM1HPK
CS-25KM1HPK
CS-32KM1HPK
CS-40KM1HPK
CS-50KM1HPK
CS-63KM1HPK
NOTES
1. Allowable length of transmission wiring between indoor/outdoor units and between the indoor unit and the
remote controller is as follows.
(1) Outdoor unit – Indoor unit:
(2) Indoor unit – Remote controller:
2. Insulated thickness:1 mm or more
• Power supply wining connections
See "INDOOR UNIT INSTALLATION" and detach the right side panel. Next, remove screw (A) and slide
front cover to the right (B) and detach. When detached, you can see terminal boards. Feed wires through
the clamp and connect to the terminal board.
• Transmission wiring connections
Feed wires through the clamp and connect to the terminal board for transmission wiring.
Depending on the number of field supplied wires, remove the clamp band and use the provided fixed
parts and clamps.
(Air discharge outlet)
Front cover
9
Power supply wiring
Field fuses
Wire
15A
H05VV-U3G
Max. 1000 m (Max. wiring length: 2000 m)
Max. 500 m
Right side panel
(A)
(B)
Terminal power for
power supply wiring
Size
Vinyl cord with sheath
Wire size must com-
or cable
ply with local codes.
(2 wire) (NOTE 2)
Remote controller wire and
connecting wire (∗)
Grounding
Clamp band (For power supply wiring)
terminal
Transmission wiring
Wire
Size
0.75 - 1.25 mm
Wiring between
unit (∗)
Terminal board for
transmission wiring
Clamp band
(For transmission wiring)
2
English