Download Print this page

Roland EGX-400 Setup Manual page 22

Hide thumbs Also See for EGX-400:

Advertisement

FlexiEngrave Configuration for
ADA/Braille Signage.
Click on the General tab and input the Y offset value which is
measured from the center position of the Raster
position of the tool in the spindle unit. This value is set under the
Drawing Offset section. The default value to start with is 1.49" and can
be adjusted to fine tune the placement of the Raster
Click Send to output the Braille job to the engraver with the supplied
offset value. The Raster
beads.
Apply the tactile material in the area where the pictogram/text is
located.
Select the Pictogram and text toolpath and configure the engraver for
cutting out the pictogram and text and insert the character cutter.
Ensure that the Drawing Offset for the Y is set to 0.000in.
Click on the Options tab and double click the 0.010in Engraver
toolpath.
Set the XY Velocity to 25mm/sec., Z Velocity to 50mm/sec. and
spindle speed to 24000RPM and click OK and click Send to output the
file.
TM
Pen attachment will insert the Raster
Pen to the center
TM
.
TM
TM

Advertisement

loading

This manual is also suitable for:

Egx-600