LIGHT OPERATION

When the lights are switched to position I (Low), the current runs through the light switch,
through the diode which reduces the voltage to the lights. The lights will operate in a low-light
condition.
When the lights are switched to position II (High), the current runs through the light switch
and directly to the lights. The lights will operate at full power.
©2012 Viking Preferred Service