Buderus 500-24C Installation And Maintenance Instructions Manual page 33

Gas wall hung boiler condensing
Hide thumbs Also See for 500-24C:
Table of Contents

Advertisement

1
Installation
Buderus 500-24C or 500-28C with external Volt Programmable Room thermostat
PL
CHF
DHW
MCW
Fig. 42
1
Condensing gas boiler 500-24C / 28C
2
radiator
3
reference room / main living area
4
other rooms
Key to abbreviations:
CB
= Connection Block
CHF
= Central Heating Flow
CHR
= Central Heating Return
DHW
= Domestic Hot Water
JB
= Junction Box/RTh Relay
LSV
= Lock Shield Valve
MCW
= Mains Cold Water
PL
= Permanent Live
PRT
= Programmable Room Thermostat
(Volt Free Contacts)
T
= Timer
TRV
= Thermostatic Radiator Valve
33
1
CB
JB
CHR
Buderus 500-24C/28C - Subject to modifications resulting from technical improvements
PRT
LSV
2
LSV
3
TRV
2
LSV
4
7215 3100-42.1TD