2100 & 4300 Millennium ACC Wood Burner
FLUE PENETRATION
Un-tested flue systems, as per AS/NZS 2918:2001, 4.6.3(b)
Fig. 6
AS/NZS2918:2001
Un-tested flue with sloped ceiling
penetration greater than 30° from
horizontal
A = 25mm
4.6.3(b)
Fig 4.6 = downward distance of
casing and 3 x ø flue distance of
the ceiling plate
Ceiling
Fig. 7
AS/NZS2918:2001
Un-tested flue with sloped ceiling
penetration greater than 30° from
horizontal
A = 25mm
4.6.3(b)
Fig 4.6 = 3 x ø flue from active flue
to heat sensitive surface
Page 8
Batten
3 x Ø flue pipe
Batten
Ceiling
ADD Cowl
Casing Cover
Spider Bracket
Approved Flashing
A
Ceiling Plate
A
flue pipe
Ø
ADD Cowl
Casing Cover
Spider Bracket
Approved Flashing
A
Ceiling Plate
A
flue pipe
Ø
7037-141D
1.QF.1F
October 12, 2015