WARNING:
For outdoor use only.
Cylinders to be used must be constructed
and marked in accordance with US DOT
specifications.
Storage indoors is permissible only if the
cylinder is removed.
CAUTION:
The minimum inlet gas supply pressure for the
purpose of input adjustment is 8 inches water
column.
The maximum inlet gas supply pressure is 13
inches water column.
The gas manifold supply pressure must be regulated
at 11 inches water column utilising an
approved regulator.
Note: 1 Pound LPG Tank is not supplied
Certification
RatedHeatInput
Fuel
Gas Supply
Manifold Pressure
Injector Size(diameter)
Safety Features
Gas Supply Pressure
TOOLS AND PARTS NEEDED FOR ASSEMBLY
TOOLS AND PARTS NEEDED FOR ASSEMBLY
TOOLS NEEDED:
Adjustable Opening Wrench, 8 Long
Philips Head Screwdriver
Leak Detection Solution ( Instructions how to make solution are included in Step 5 )
Specification
CSA
10000BTU/HR
Propane-LP
16.4ozOR 20 Lb.LP-Gas cylinder
11.0 inches W.C
0.91mm
Flame failure device,Tilt switch&Oxygen Depletion Safety(ODS)pilot
Max 150PSI,Min5PSI
2