2.

WIRELESS REMOTE CONTROLLER

FEATURES
Simple function setting
z
Setting of the air conditioner selection function is performed by remote controller.
Built-in timers
z
Select from four different timer programs (ON / OFF / PROGRAM / SLEEP).
Program timer
z
The program timer operates the on and off timer once within a 24 hour period.
Sleep timer
z
The sleep timer function automatically corrects the temperature thermostat setting according to
the timer setting to prevent excessive cooling and heating while sleeping.
Cooling operation/dry operation
When the sleep timer is set, the set temperature
automatically rises 1 °C every hour. The set
temperature can rise up to a maximum of 2 °C.
Timer setting
60min.
1 °C
Switching remote controller signal code
z
Mixed-up
I.U.
I.U.
I.U.
I.U.
Code selector switch eliminates unit
being wrongly switched.
(Up to 4 codes can be set.)
*I.U.=Indoor unit
4 mode timer setup available (ON / OFF / PROGRAM / SLEEP).
Easy operation.
Easy to change signal code (max. 4 units) by button operation.
2 °C
Set
temp.
After code change
A
B
C
D
I.U.
I.U.
I.U.
I.U.
A
B
C
D
- (01 - 03) -
Heating operation
When the sleep timer is set, the set temperature
automatically drops 1 °C every 30 minutes. The set
temperature can drop to a maximum of 4 °C.
1 °C
2 °C
30min.
60min.
90min.
Timer setting
Set
temp.
3 °C
4 °C