Vulcan-Hart HDR V series Operation Manual page 7

Table of Contents

Advertisement

CONNECTION OF MANIFOLDS IN BATTERY
Two or more ranges can be coupled together at the manifold by removing the front control panel to
make necessary connections. Be sure to cap open ends. To connect:
1. In a large battery of eight or more ranges, gas should be fed from both ends of the battery.
"T" gas connections can be installed whenever necessary for increased gas supply.
For further details, consult your gas company.
2. Align the front edge of the ranges and adjust the legs to bring the manifolds together
inline for connection. Clamps may be used to pull the ranges together.
3. Connect the unions between the gas manifolds.
4. Use the battery clip at the back of the range base to hold the units together.
5. Before replacing the manifold covers, check all gas connections for leaks. (See GAS
CONNECTIONS in this manual. )
If appliance has rear gas connection, carefully check for open gas lines.
The gas pressure regulator must have proper outlet pressure capacity for this battery application.
— 7 —