Notes on safety
V
CAUTION!
Transport the device only in its original packaging or in packaging
which protects it from knocks and jolts.
Installation and operation
V
CAUTION!
For your safety, note the warning labels when removing modules
from the server.
Beware of the energy hazard at the midplane contacts. A short-circuit
on these contacts may damage the system.
If the basic unit is integrated in a rack installation that receives power
from an industrial (public) power supply network with the IEC309
connector, the (public) power supply protection must comply with the
requirements for the non-industrial (public) power supply networks for
the type A connector.
For the PRIMERGY BX600 S3 basic unit only 2100W PSUs are
allowed (Product no. A3C40073262)! The 1200W PSUs of the
PRIMERGY BX600 S1 basic unit is not allowed for the PRIMERGY
BX600 S3 basic unit.
The 2100W PSU is not allowed for the PRIMERGY BX600 S1 basic
unit.
Make sure that the PRIMERGY BX600 S3 basic unit is connected to
the mains for at least one minute before pressing the power ON/OFF
button to switch the system ON.
The system automatically adjusts to a mains voltage between 200 -
240 V. The system must only be operated if the voltage range set on
the basic unit matches the local mains voltage.
This device has safety-tested power cables and must only be
connected to 16 Amp grounding outlets, a power distribution unit
(PDU) or CEE outlets.
If there are not enough grounded power outlets available in the rack,
use power sockets outside of the rack.
The power switch does not disconnect the device from the mains
voltage. The power cable must therefore be pulled out of the power
outlet.