Output Bin Tests - Oki MB 780 Service Manual

Hide thumbs Also See for MB 780:
Table of Contents

Advertisement

OUTPUT BIN TESTS

Feed Tests (output bins)
Use these tests to verify that media can be fed to the standard output bin. No information
is printed on the media fed to the output bin, because the printhead is not engaged during
this test. These tests can use any Next media size or envelope supported by the printer.
To run the Feed Tests for the output bins:
• Select Feed Tests from the OUTPUT BIN TESTS.
• Select the output bin you want the paper to exit into.
• Select either Single or Continuous.
Single - feeds one sheet of media from the selected source. Continuous - media
continues feeding from the selected source until Stop is pressed. Touch Back to return to
OUTPUT BIN TESTS.
Sensor Test (standard output bin)
This test is used to verify if the standard bin sensor is working correctly.
To run the Sensor Test for the standard bin:
• select Sensor Test from OUTPUT BIN TESTS
• select Standard Bin from Sensor Tests
• Manually actuate the bin sensor by moving the flag in and out of the sensor, and
the display changes. The following screen is displayed:
• Press Stop to exit the test
Bin Empty: empty or Bin Empty: full
20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mb790

Table of Contents