Case Front Controls - Lincoln Electric FLEXTECTM 650 Operator's Manual

Table of Contents

Advertisement

FLEXTEC
TM
650
CASE FRONT CONTROL DESCRIPTIONS
(See Figure B.1)
1. Power Switch: Controls input power to the
Flextec 650.
2. Voltage Display Meter
3. Amperage Display Meter
4. Thermal LED: A yellow light that comes on
when an over temperature situation occurs.
Output is disabled until the machine cools
down. When cool, the light goes out and output
is enabled.
5. Weld Process Selector Switch: A rotary switch
that toggles through the five available weld
modes for the Flextec 650 – CC-SMAW; CC-
GTAW; CV; CV-Innershield; CV-SAW.
6. Hot Start Control Dial
7. Output Control Dial: Sets the output current or
voltage for the selected weld process.
8. Local/Remote Selector Toggle Switch: Sets the
control of the output to local (output control
knob) or remote (K857 hand amptrol or K870
foot amptrol).
9. Arc Force Control Dial
10. Weld Terminals On/Remote selector switch.
11. 14 pin wire feeder circular connector.
12. 115V or 42V wire feeder selector switch.
13. Circuit breaker reset buttons for the 14 pin
wire feeder connector.
14. 6 pin remote circular connector.
15. Positive and negative welding output studs.
16. Wire Feeder Voltmeter Polarity Selection
Switch.
17. VRD™ (Voltage Reduction Device) Indicator
Lights
FIGURE B.1