CABLE CONNECTIONS

See FIGURE A.2 for locating 6-pin and 14-pin con-
nectors on the front of the FLEXTEC™ 650.
6-PIN REMOTE CONTROL CONNECTOR
Function
Pin
6-pin remote
A
77 Remote potentiometer, 10K
control con-
B
76 Remote potentiometer, wiper
nector for
C
75 Remote potentiometer, common
remote or
D
Trigger, common
Trigger, input
hand/foot
E
amptrol.
F
Ground
14-PIN CONNECTOR FOR WIRE FEEDER
Function
Pin
14 pin con-
A
115 VAC
nector for
B
Ground
wire feeder
C
Trigger, Common
Trigger input
connectivity.
D
E
77 Remote potentiometer, 10K
F
76 Remote potentiometer, wiper
G
75 Remote potentiometer, common
H
Voltage Sense (21)
Motor (42 VAC)
I
J
115 VAC
K
Motor (42 VAC)
L
M
N
FIGURE A.2