Refrigerating Cycle Block Diagram - Samsung ASH-0906ER Service Manual

Table of Contents

Advertisement

7-2 Refrigerating Cycle Block Diagram

INDOOR UNIT
T
1
Heat
exchanger
(Evaporator)
T
2
Refrigerating cycle temperature and pressure
Operating Condition
Standard
Cooling
Max over load
Low temp
Standard
Heating
Max over load
Deice
7-2
Capillary tube
2-way valve
Liquid side
Gas side
3-way valve
STD Pressure
Piping Temp.
(kg/cm
2
G)
T1
3-WAY V/V
4.5~5.5
10~12
-
16~18
-
1~4
18~20
32~36
-
36~40
-
28~32
OUTDOOR UNIT
Check valve
Capillary tube
Heat
exchanger
(Condenser)
4-way valve
Compressor
UseTemp. Condition (°C)
Indoor
T2
DB
WB
10~12
27
19
14~18
32
23
1~4
21
16
60~70
20
-
65~75
27
-
40~45
20
-
Cooling
Heating
Gas leak check point
Outdoor
DB
WB
35
24
43
26
21
16
7
6
21
16
2
1
Samsung Electronics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ash-1206er

Table of Contents