Operating Instructions and Installation
3-2-2(e) Outdoor unit installation
Wiring connection
1. Remove the cover-valve.
2. Firmly connect the cable connector with EL-connector. (4. pin)
3. Fasten the M4 ring terminal to the hole marked
4. Firmly fix the ass'y cable with clamp wire holder.
5. Assemble the cover-valve.
6. To prevent the entry of water, form a trap of the ass'y cable as
illustrated in the installation diagram of indoor and outdoor unit.
Installation of drain line
In heating and de-ice operation, condensed water may be generated.
Install drain line as following procedure.
1. Insert drain plug into hole and then connect drain hose to drain plug.
*Inside diameter of drain hose is 18mm
Grounding
(The parts for this work are optional)
● The grounding screw hole is located in the position shown.
● A grounding terminal can be found on the outdoor unit as
illustrated.
3-8
Drain hole
Drain plug
Grounding screw hole
EL Connector
Clamp Wire Holder
Screw
Grounding Screw Hole