5-2-4 When the UP/DOWN Louver Motor Does Not Operate. (Initial Diagnosis)
1)
Checklist :
(1) Is input voltage normal? (198-264V~)
(2) Is the UP/DOWN louver motor properly connected with the connector (CN61)?
2)
Troubleshooting procedure
Remove power cord and plug in again in approx. 5 seconds.
Is operating lamp blinking in 3 minutes and then lamp off?
Does operation start when swing button of the remote
control unit pushed?
Voltage at pin #33-#36 of micom (IC01) change?(Squarewave)
Volatge at pin #10-#13 of IC02
(KA2657change?(Squarewave)
UP/DOWN louver motor is faulty.
Samsung Electronics
N
Y
Y
N
N
Y
N
Y
Check as in the procedure "No Power
parts". Refer to page 5-2.
Normal
Micom (IC01) is faulty.
Driver IC02 (KA2657) is faulty.