12) Removal of Bypass Servo
a. Remove fan motor (Refer to point 16)
b. Remove 3 pin connector
c. Remove 2 pin connector
d. Remove 6 pin connector and 5 pin connector
e. Remove bracket for water connection tube.
f.
Removal of inlet water connection
g. Remove bypass servo and water flow servo
h. Remove fitting screws of bypass servo
i.
Flow sensor and water flow servo
REU-K2430WG-AK (Envirosmart
)
13) Removal of Anti Frost Switch
a. Remove 2 pin connection for anti frost switch
b. Remove Anti Frost switch
c. Anti Frost switch
- 35 -
Issue 1 - 16/12/09 ©Rinnai